Experimental Study on Electro-Thermal Coupling Model Applied in Computation of Radial Temperature Distribution of RIP Oil-Gas Bushing Condenser

ZHANG Shiling,PENG Zongren,LIU Peng,LI Bo,HU Wei,CHENG Huanchao
DOI: https://doi.org/10.13335/j.1000-3673.pst.2012.12.018
2012-01-01
Abstract:Due to the direct impact of temperature distribution of 550kV resin impregnated paper(RIP) oil-gas bushing condensers on the long-term secure and stable operation of the bushings,the radial temperature distribution within the bushing condenser must be researched for the trial-manufacture of the prototype of RIP oil-gas condenser bushing.By means of establishing an electro-thermal coupling model of the bushing condenser,the radial temperature distribution law of the bushing condenser under linear material condition is derived;then applying finite element model of electro-thermal coupling the established theoretical model of radial temperature distribution is extended to the nonlinear material condition;finally experimental measurement of local temperature points of bushing condenser is performed.Measured results show that the highest temperature of 550kV RIP oil-gas bushing appears near center conductor and the temperature is about 95℃;the calculated radial temperature of the bushing under nonlinear material condition is lower than that under linear material condition;the thermal breakdown voltage of bushing condenser under rated current is 538kV,which is higher than the maximum operation phase voltage of the bushing.
What problem does this paper attempt to address?