Thermal Simulation of AC Contactor

SHEN Xu,CHEN Le-sheng,SHEN Qian-hong,FAN Xian-ping,YANG Hui
DOI: https://doi.org/10.3969/j.issn.1671-8887.2012.03.009
2012-01-01
Abstract:Using the techniques of visual simulation of ANSYS,the thermal simulation of a typical AC contactor was achieved.This contactor has a single heat source(the electrical contact group),and the major modeling steps are: 3D model building,finite elements division,preprocess(including element types,material properties,contact conditions,etc),loading constraints(including tension,current,atmosphere convections,etc) and post-process data analysis.The simulation result shows that the highest temperature appears at the region of contact,the temperature results have a tiny difference between Ag and Ag composite Ag(SnO2)7(In2O3)3,and the rise of temperature rests in the safety operating temperature range.