Numerical Simulation on Interior Flow in Superheater for Supercharged Marine Boiler and Study on Flowrate Distribution
Zhi-gang LI,Ren-qiu JIANG,Yan-jun LI,Bao-zhi SUN
DOI: https://doi.org/10.3969/j.issn.1000-4882.2006.04.006
2006-01-01
Abstract:The nonuniformity of steam mass flowrate in parallel tubes of superheater is one of the major factors that lead to difference in tube wall temperature,local overheating and even tube rupture.In view of the complexity of superheater structure for supercharged marine boiler,three-dimensional model is established for the overall steam space inside superheater with Pro/Engineer.Selecting more reasonable boundary conditions and employing fundamental equations of fluid dynamics and standard double-equation k-e turbulence model as mathematical model,three-dimensional numerical simulations are made for steam flow in overall superheater with different structural parameters,and patterns of mass-flow-rate distribution are directly obtained from the simulation calculation results.Various structural factors that influence flowrate nonuniformity are analyzed,summed up and verified.Computational results show that both nonuniformity of flowrate and unevenness of heat load within each section are remarkably reduced by the special superheater structure and pass arrangement,in which densely and evenly disposed thin tubes along the header axis instead of single wide connecting conduit are adopted as steam inlets,and in which baffles are utilized to divide the second and third pass tubes into three sections along the furnace width.The flowrate nonuniformity falls within 0.99~1.02 for pass two,which is negligible,and within 0.955~1.035 for pass three.Drop of steam pressure inside the chambers along the flow direction is effectively reduced by the sloping baffles,so that nonuniformity of flowrate in the third pass tubes can be intentionally adjusted by modifying the baffle angle,so as to coincide with the heat load distribution in the furnace chamber.Consequently the difference in tube wall temperature is minimized by the baffle obliquity and pass configuration.Calculation results also show that,when other structural features,such as pass arrangement,baffle configuration,and method and position of tube importing and exporting,remain unchanged,the flowrate nonuniformity is determined by the ratio of the total area of cross-sections of tubes on unit header length to the area of cross-section of the header,and the ratio of average tube length to header length.Flowrate distribution tends to be more uniform with the decrease of the former ratio and the increase of the latter ratio.