Discussion on the Life Test Method of Motor Train Vacuum Circuit Breaker under Frequent Interruption

Le-cheng OUYANG,Guang-ning WU,Tian-zhi LI,Guo-qiang GAO
DOI: https://doi.org/10.13296/j.1001-1609.hva.2012.09.016
2012-01-01
Abstract:Motor train vacuum circuit breaker(VCB) is the key part of power supply control system,which is very important to safe and stable operation of motor train.The working conditions of motor train VCB are very peculiar,which makes its life-span characteristic very different from common VCB in power system.So the life test methods for common VCB are not suitable for motor train VCB.In order to test the lifetime of motor train VCB,a new life test method is put forward for the CRH2A type motor train VCB,including frequency withstand voltage test,impact withstand voltage test,mechanical endurance test,and contact resistance measurement of contact terminal in arc extinguishing chamber.Consequently,the relationships between the test data and the breaking number can be obtained to analyze the life limits of the motor train VCB.