Study on vehicle-mounted vacuum circuit breaker switching overvoltage and its protection

Le-cheng OUYANG,Guang-ning WU,Guo-qiang GAO,Tian-zhi LI
DOI: https://doi.org/10.3969/j.issn.1003-3076.2013.02.019
2013-01-01
Abstract:The vehicle-mounted vacuum circuit breaker will open the circuit when locomotive regenerative braking or passing the articulated phase insulator.It will produce high operating overvoltage.Simplified circuit model is established in this paper according to the power supply system of locomotive.The transient process of vacuum circuit breaker interruption is simulated using EMTP.Based on the simulation results,influencing factors of overvoltage and two different overvoltage protection devices are analyzed.The parameters of the protectors are also determined.The results indicate that,the greater the ground capacitance of transformer is,the lower the overvoltage peak will be;MOA can limit the amplitude of overvoltage obviously,but it is not effective enough to reduce the gradient and frequency of overvoltage;RC device can reduce the amplitude、steep degree and frequency of overvoltage well.
What problem does this paper attempt to address?