Operational models of bioleaching for removal of Cr in tannery sludge

Wang Dianzhan,Zhou Lixiang
DOI: https://doi.org/10.3969/j.issn.1673-9108.2006.10.026
2006-01-01
Abstract:It is a perspective and cost-effective approach to remove heavy metals in tannery sludge by bioleaching.A set of stirred tank bioreactor,mainly consisting of four parts——agitation with impeller,aeration,heating parts,and a 50 L container,was designed and used in this study.Under a fixed aeration at a rate of 0.9 L/min and temperature of 28 ℃,continuous stir model and intermittent stir models with stirring for 30 min followed by stopping for 30 min,45 min,and 60 min were employed to study their performances of bioleaching for tannery sludge.The results showed that pH of tannery sludge in bioreactor could be declined to less 2,ORP was increased to 530~545 mV,and 99% of Cr were removed regardless of continuous or intermittent stir models.However,it took 48 h,60 h,84 h,and 156 h to accomplish bioleaching for continuous stir model,and intermittent stir models with stirring for 30 min followed by stopping for 30 min,45 min,and 60 min,respectively.In the light of the energy consuming and bioleaching efficiency in different models,the intermittent stir model with stirring for 30 min followed by stopping for 30 min was found to be a cost-effective model with an energy reduction of 25% compared to continuous stir model.