Rapid Determination of Wastewater COD for Sugar Refinery by TIR/ATR Spectroscopy

Qiang JI,Tao PAN,Xin-yan LIAO
DOI: https://doi.org/10.3969/j.issn.1008-1402.2011.03.011
2011-01-01
Abstract:The rapid determination method of wastewater chemical oxygen demand(COD) for sugar refinery was established by FTIR/ATR spectroscopy.The optimal spectral analysis model was established based on partial least squares(PLS) and Savitzky-Golay(SG) smoothing method.By establishing the computer algorithm platform,for any combination of 540 SG smoothing modes and 1-40 PLS factors,the SG-PLS models were constructed respectively.The SG smoothing mode of the optimal degree po al model is the 2nd order derivative smoothing,6lynomial,51 smoothing points,and the corresponding PLS factor(F),the root mean square error of prediction(RMSEP) and prediction correlation coefficient(RP) are 11,24.4 mg/L and 0.968 respectively.The prediction relation was very high and this model was obviously superior to the direct PLS model without SG smoothing.
What problem does this paper attempt to address?