Determination of Chemical Oxygen Demand in Wastewater by Near-Infrared Spectroscopy

HE Jin-cheng,YANG Xiang-long,WANG Li-ren,GUO Xi-shan
DOI: https://doi.org/10.3785/j.issn.1008-973x.2007.05.010
2007-01-01
Abstract:To rapidly determine the pollution extent of wastewater,the potential of near infrared(NIR) spectroscopy for measurement of chemical oxygen demand(COD) in wastewater was investigated.A total of 180 samples including 158 wastewater samples collected from Hangzhou Wastewater Treatment Plant and 22 COD standard solutions(potassium hydrogen phthalate(KHP)) prepared in laboratory.Transmission spectral measurements and dichromate method tests of 180 samples were carried out.Spectral data from 800 to 2 600 nm were collected using InGaAs detectors at 0.717 nm resolution using a 10 mm transmission pathlength.Calibration models were developed from dichromate method as a reference method and NIR data using partial least squares(PLS) regression.The calibration model of standard solutions gave correlation coefficients of 0.999 9 and root mean square error of cross validation(RMSECV) of 15.14 mg/L,and the calibration model of wastewater samples gave correlation coefficients of 0.945 3 and root mean standard error of prediction(RMSEP) of 35.4 mg/L.The results shows that NIR spectroscopy is promising for detecting COD in wastewater.