Clinical Evaluation of Regional Electric Impedance Pneumography and Scintigraphy in Measurement of Pulmonary Perfusion and Ventilation

YANG Wen-lan,LIU Jin-ming,JIA Hai-quan,MA Hui-jun,ZHEN Wei,HUANG Cai-liu
DOI: https://doi.org/10.3969/j.issn.1008-0392.2007.02.013
2007-01-01
Abstract:Objective To evaluate the clinical capability of regional electric impedance pneumography and scintigraphy in measurement of pulmonary perfusion and ventilation.Methods Thirty-two patients with different respiratory diseases underwent regional electric impedance pneumography and scintigraphy,the pulmonary perfusion and ventilation were obtained and recorded.Results The pulmonary perfusion results obtained by regional electric impedance pneumography in the left lower region was lower than the results measured by scintigraphy,there were significant differences(P0.05),and no difference in other pulmonary regions.The pulmonary ventilation results obtained by regional electric impedance pneumography in both upper regions were higher and in the left middle region were lower than the results measured by scintigraphy,there were significant differences(P0.05),and no difference in other pulmonary regions.Conclusion The result obtained by regional electric impedance pneumograph can not replace the result obtained by scintigraphy at present,but this is also a quick,simple and convenient measurement to get additional parameters of the pulmonary perfusion and ventilation.
What problem does this paper attempt to address?