Regional Pulmonary Ventilation Assessment Method and System Based on Impedance Sensing Information from the Pentapulmonary Lobes

Yapeng Zhang,Chengxin Song,Wei He,Qian Zhang,Pengcheng Zhao,Jingang Wang
DOI: https://doi.org/10.3390/s24103202
IF: 3.9
2024-05-18
Sensors
Abstract:Regional lung ventilation assessment is a critical tool for the early detection of lung diseases and postoperative evaluation. Biosensor-based impedance measurements, known for their non-invasive nature, among other benefits, have garnered significant attention compared to traditional detection methods that utilize pressure sensors. However, solely utilizing overall thoracic impedance fails to accurately capture changes in regional lung air volume. This study introduces an assessment method for lung ventilation that utilizes impedance data from the five lobes, develops a nonlinear model correlating regional impedance with lung air volume, and formulates an approach to identify regional ventilation obstructions based on impedance variations in affected areas. The electrode configuration for the five lung lobes was established through numerical simulations, revealing a power–function nonlinear relationship between regional impedance and air volume changes. An analysis of 389 pulmonary function tests refined the equations for calculating pulmonary function parameters, taking into account individual differences. Validation tests on 30 cases indicated maximum relative errors of 0.82% for FVC and 0.98% for FEV1, all within the 95% confidence intervals. The index for assessing regional ventilation impairment was corroborated by CT scans in 50 critical care cases, with 10 validation trials showing agreement with CT lesion localization results.
engineering, electrical & electronic,instruments & instrumentation,chemistry, analytical
What problem does this paper attempt to address?
The problem this paper attempts to address is: how to achieve accurate assessment of the ventilation status in the five lung lobe regions through bioimpedance measurement technology. Specifically, existing methods based on overall thoracic impedance cannot accurately capture changes in local lung air volume, leading to lower accuracy in the calculation of ventilation parameters and the inability to provide regional ventilation parameters. Therefore, this study proposes an evaluation method based on impedance information from the five lung lobe regions. By designing a specific electrode configuration to achieve focused measurement of impedance changes in each lung lobe region and establishing a nonlinear model to correlate regional impedance with changes in lung air volume, the accuracy of lung function parameter calculations is improved, and indicators for assessing regional ventilation disorders are provided.