Abstract:Ultrafiltration(UF) membrane technology has become one of the most promising high-techs in water treatment.However,its applications are significantly limited because of membrane fouling.A gas/liquid two-phase flow cleaning method was put forward and its performance on cleaning membrane modules fouled in the complexation-ultrafiltration process was studied.Effects of cleaning methods(gas flushing,water backflushing,chemical backflushing and gas-liquid two-phase flow with either water or chemical as cleaning solution) on the flux recovery were compared.Results show that the gas/liquid two-phase flow method can recover the membrane flux most with the minimum cleaning time.Effects of gas pulse time(tc),gas pulse interval(ti),velocity ratio of gas to liquid(Rg/l) on gas/liquid two-phase flow performance were investigated.When ti is 10 s and Rg/l is 20∶1,the flux was recovered most with tc of 15 s and 25 s.When tc is 15 s and Rg/l is 20∶1,the flux is recovered most with 20 s ti.When tc is 15 s and ti is 10 s,the two-phase flow cleaning method with water as cleaning solution can recover the flux most with Rg/l = 80∶1 and the two-phase flow cleaning method with HCl as cleaning solution can recover the flux most with Rg/l = 40∶1.Results indicate that the gas/liquid two-phase flow cleaning method can effectively remove UF membrane foulants in the complexation-ultrafiltration process and can be called a green membrane cleaning method.