Operation and Optimization of Ultrafiltration/Nanofiltration Hybrid Membrane Process

Xue-wu ZHU,Xiao-xiang CHENG,Bai-ming XIE,Hui QIU,Qian CHEN,Fang-shu QU,Gui-bai LI,Heng LIANG
DOI: https://doi.org/10.19853/j.zgjsps.1000-4602.2017.05.003
2017-01-01
Abstract:Through advanced treatment of Qiantang River by UF/NF hybrid membrane process,the effects of operation parameters on effluent quality and the physical and/or chemical cleaning performance were discussed.The experimental results showed that the increase of flux,the extension of operation cycle,and the increase of concentrated water discharge cycle all could improve the effluent quality to some extent,but membrane fouling was aggravated at the same time.With the increase of operation pressure and cross-flow velocity,the membrane flux and effluent quality increased.Membrane fouling was aggravated with the increase of operation pressure and decreased with the increase of cross-flow velocity.As recovery rate increased,the effluent quality was deteriorated and membrane fouling was accelerated.With the extension of running time,the effect of physical cleaning on the recovery of membrane flux decreased,timely chemical cleaning could recover the membrane flux effectively and prolong the working life of the membrane.
What problem does this paper attempt to address?