Magnetic Resonance Perfusion Weighted Imaging in Normal Pancrease: Comparison of Two Sequences

张晶,田建明,郝强,王莉
DOI: https://doi.org/10.3969/j.issn.1006-5741.2008.06.014
2008-01-01
Abstract:To determine which sequence is better at MR perfusion weighted imaging in normal pancreas by comparing sequence FLASH 2D and VIBE.To investigate the difference of perfusion between head、neck、body and tail of normal pancreas.Twenty-eight healthy volunteers underwent MR perfusion with sequence FLASH 2D and VIBE.The interval of the two sequences was 24 hours.Compared the value of signal-to-noise rate(SNR) in the two sequences and a statistical analysis was done.Region of interest(ROI) in aorta、head、neck、body and tail of pancreas were drawn respectively,then their time-intensity curves(TIC) were got.The time to peak(TTP) and the steepest slope(SS) were calculated.Then the following statistical analysis were performed:perfusion gained with different sequences and perfusion gained from head、neck、body and tail of pancreas.①The SNR of FLASH 2D and VIBE were 55.71±11.44、111.52±29.35(P0.05).②The TTP of head、neck、body and tail of normal pancreas were 24.33±3.74s、23.82±2.14s、23.75±3.94s、23.47±2.40s respectively,and the SS were 30.23±4.66、29.69±3.39、31.02±2.54、30.83±2.60.There was no difference between perfusion of pancreas head、neck、body and tail(P0.05).Sequence VIBE can be applied in whole-pancreas MR perfusion,and the image has higher SNR.Its results are reliable.
What problem does this paper attempt to address?