The Comparative Study of Multiple Sequences on Pancreatic MR Imaging

ZHU Xi-xu,CHEN Jun-kun,LU Guang-ming,LI Hai-hua,HU Xin-qiu
DOI: https://doi.org/10.3969/j.issn.1002-1671.2000.10.009
2000-01-01
Abstract:Objective:Pancreatic signal intensity,s ignal to noise(S/N) and signal difference to noise(SD/N)were compared and analyz ed between spin-echo(SE),breath-holding fast low angle shot(breath-holding FLASH ),FLASH and fat suppressed(FS)sequences in order to improve pancreatic image qua lity.Methods:50 cases of normal pancrease were examined using s equences including SE breath-holding FLASH FLASH and FS at Siemens Magneton impa ct 1.0 T.Scanning parameters used on FS sequences were consistent with that used on SE,breath-hokling FLASH,FLASH respectively.Results:Pancreas was isointensity,fat around pancrease sho wed hyperintensity and blood vessel showed black because of flow void on T 1 we ighted and T 2 weighted SE sequences.Pancreatic signal intensity on SE/T 1WI a nd FLASH was higher than other sequences(p0.01,respectively).Pancreatic signal intensity on FS FLASH was higher than other FS sequences(p0.01).SE/T 2WI had the worst S/N(p0.01)while FLASH had the poorest SD/N(p0.001)on non-FS MR im ages.FS FLASH had the highest S/N(p0.05),but no significant difference were fo und on FS sequences.Conclusion:Our results suggest that SE and breath-holding FLASH may be choosed in routine examination of pancrease.FS sequences should be selected as supplemental and advanced pancretic examination. [