Research on Grounding Fault Protection for Shipboard Medium Voltage DC System

Jin Panfeng,Bi Daqiang,Meng Suimin
DOI: https://doi.org/10.3969/j.issn.1003-4862.2013.05.002
2013-01-01
Abstract:Because of the particularity of the shipboard medium voltage DC power grid, differential and inverter protection can not meet the reliability requirements of total system protection. Based on a shipboard medium voltage DC system, grounding fault characteristics of the neutral point grounding by the high resistance is researched, and the disadvantage of differential protection and inverter protection is analyzed, thus the grounding protection scheme of the zero sequence differential protection and the characteristic frequency voltage protection via electronic current transformer (ECT) are proposed, and the sensitivity of protection is improved in this method. The simulation analysis validates the feasibility of protection methods by SIMULINK.