Suppression Method of Conducted EMI in Motor Driven System

Jiang Baojun,Sun Li,Sun Yaxiu,Yan Dong
DOI: https://doi.org/10.3969/j.issn.1001-2095.2006.05.002
2006-01-01
Abstract:The conducted EMI is caused by the current influx into sensitivity device finally.This paper proposed a new leak current suppression method based on the analysis of transfer path of leak current in motor system.The proposed method is that the metal shielding layer with high conductivity is placed between power electronic device and heat sink to reduce parasitical capacitance between the two devices and the leak current of system.This method has value in application,and its simplicity and effectiveness are confirmed by experiment.
What problem does this paper attempt to address?