The Improvement on the Determination Method of Anionic Surfactant in Surface Water

CHEN Li-ke,LIU Miao,CHNE Song-yue,LIU Nan,LENG Su,LI Guang-zhu,YANG Xin-ran,WANG Ye
2011-01-01
Abstract:Water samples are filtered through 0.45 m microporous films first.It comprises extracting ion pair with CHCl3 twice,10 mL at a time.When emulsification occurs,It is an effective way to break of the emulsification layer by stirring with a clean copper wire.There is no significant differences between the result of samples determination by using the improved methods and the one by using international standard method.Both of the accuracy and precision of the method meet the quality control requirements,which is more efficient,operationally simpler and more suitable for the determination.
What problem does this paper attempt to address?