Simultaneous Determination of Two Sulfonamides in Environmental Water by Temperature-Assisted Ionic Liquid Dispersive Liquid-Liquid Micro-Extraction Coupled with High Performance Liquid Chromatography
Angang CHANG,Kai ZHOU,Jing JIANG,Xiangyang WU,Zhen ZHANG
DOI: https://doi.org/10.7524/j.issn.0254-6108.2013.02.017
IF: 4.236
2013-01-01
Environmental Chemistry
Abstract:In this study, 1-octyl-3-methylimidazolium hexafluorophosphate ([ C8 MIM] [ PF6 ]) was selected as extraction solvent, and temperature-controlled ionic liquid dispersive liquid-liquid microextraction ( TC-IL-DLLME) was introduced to analyze two sulfonamides (SAs), sulfadimethoxine (SDM) and sulfamethoxazole (SMZ), in environmental water by coupling with high performance liquid chromatography (HPLC). Several parameters that could affect extraction performance were optimized, including the type and volume of extraction and dispersive solvents, sample pH, salinity, temperature, extraction and centrifugation time. Under the optimized conditions, the established method offered good linear range (2—200 μg·L - 1 ), low detection limits (SDM, 1. 22 μg·L - 1; SMZ, 0. 50 μg·L - 1 ), good reproducibility (relative standard deviation, RSD: SDM, 1. 94% ; SMZ, 1. 90% ; n = 7), and good recoveries (SDM, 88. 7% ;SMZ, 101. 3% ;n = 7). In addition, the method was applied to the determination of SAs in environmental water samples, and satisfactory recoveries were obtained (63. 0% —124. 0% ; RSD, 2. 1% —4. 9% ; n = 6), which confirmed that this method was reliable and could be widely used to determine SAs in aqueous system.