CALCULATION OF LOAD-BEARING CAPACITY AND DEFORMATION IN SINGLY-STEPPED SINUSOIDAL CORRUGATED WEB COLUMN

Guo Yanlin,Liu Feng,Dou Chao,Jiang Ziqin
DOI: https://doi.org/10.13204/j.gyjz2012.07.013
2012-01-01
Abstract:The effect of shear deformation in singly-stepped sinusoidal corrugated web columns on the effective length factors is analyzed,and theoretically derived formulation was presented firstly.Compared with approximately "The Code for Design of Steel Structures"(GB 50017—2003) and the FEA results,it was concluded that the verification of global stability in the singly-stepped sinusoidal corrugated web columns is proposed by combing the effective length factors given by GB 50017—2003 with the design formula from Technical Specification for Sinusoidal Web Steel Structures(CECS 290∶2011) which reflects the effect of shear deformation of corrugated web.And the formula for calculating the lateral deformation of singly-stepped sinusoidal corrugated web columns was given.Finally,the structural construction details and design of shoulder-beam of singly-stepped column were introduced.
What problem does this paper attempt to address?