DETERMINATION OF THEANINE IN RAT SERUM AND BRAIN BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY AND FLUORESCENCE DETECTION

SHEN Hui,SHEN Xin-nan,WU Min
DOI: https://doi.org/10.13325/j.cnki.acta.nutr.sin.2011.01.014
2011-01-01
Abstract:Objective To establish a HPLC method of determining theanine in rat serum and brain tissue.Method Using ODS-SP C18 chromatography column(4.6 mm×250 mm,5μm),the mobile-phase was 0.1 mol/L monopotassium phosphate buffer solution(pH 6.0):THF: methanol =63:2:35,the HPLC system with fluorescence detection(FL) was used to examine the theanine in rat serum and brain tissues with pre-column derivatization with o-phthalaldehyde(OPA) in the presence of the internal standard homoserine.Flow rate was set at 0.85 ml/min.The excitation wavelength was 340 nm while the emission wavelength was 455 nm.Results The method had good linearity with the concentration ranges of 1-20 μmol/L for theanine.The correlation coefficient(r) was 0.9997.The intraday precisions(RSD,%) of theanine with the concentration of 1 μmol/L,10 μmol/L,20 μmol/L were 3.51,1.58,0.75,while the interday precisions(RSD,%) were 4.54,4.25,2.87.The recoveries were between 91.8%-99.1%.The detection limits was 0.02 μmol/L.When 200 mg/kg·bw of theanine was intragastrically administered to rats,the serum concentration of theanine reached its highest level during 0.5-1.0 h after i.g.,while the highest level of brain appeared after 5 h.Conclusion This improved high performance liquid chromatography(HPLC) with fluorescence method is sensitive,and reproducible.It can separate and detect theanine of serum and brain tissue in rat effectively.
What problem does this paper attempt to address?