Dosimetry Comparison of 3-Dimensional Conformal Radiation Therapy and Intensity Modulated Radiation Therapy Plans for Para-aortic Lymph Node Tumor Metastasis

LI Tao,GONG You-ling,JIANG Xiao-qin,BAI Sen,LI Zhi-ping
2008-01-01
Abstract:Objective: To compare dosimetry of 3D-CRT and IMRT plan for para-aortic lymph node tumor metastasis. Methods: For 12 patients, 3D-CRT and IMRT plans were performed, and plans were compared according to dose-volume histogram. Results: The Dmax for GTV in IMRT plan and the conformity index were better than those in 3D-CRT plan. Also, the D5 of kidneys in IMRT plan were statistically lower than those in 3D-CRT plan. In dose study of intestine, D5、D10、D20、D30 and Dmean were all statistically lower in IMRT plan than the parameters in 3D-CRT plan. Conclusions: In radiotherapy for para-aortic lymph node tumor metastasis, IMRT effectively separated GTV and the organs at risk, escalating the dose for tumor and limiting the dose for these organs as could as possible. IMRT should be applied in clinic more widely.