CT Findings of Lung Ischemia Reperfusion Injury in Canine:Correlation with Pathophysiology

路莉,张龙江,陈波,王梅,吴垠垠,葛洪,吴新生,赵艳娥,卢光明
DOI: https://doi.org/10.13437/j.cnki.jcr.2012.02.001
2012-01-01
Abstract:Objective To evaluate CT findings and associated pathophysiological basis of pulmonary ischemic reperfusion injure(PIRI) in dog models with the closed pectoral balloon embolization method.Materials and Methods Eleven health hybrid dogs were selected for establishing PIRI model.Right femoral vein was punctured with Seldinger method and left pulmonary artery was blocked with the balloon for 2 hours.CT plain scan was performed,pulmonary arterial pressure were measure and blood sample was collected at 6 time points,including pre embolisation,2 h after establism,1 h,2 h,3 h,4 h after reperfusion.Immediately after CT scan at 4 h after reperfusion,the dogs were sacrificed and lung specimens were harvested.Dynamic CT findings,pulmonary artery pressure,blood gas results and histopathological findings were analyzed.Results PIRI models were successfully made in 10 dogs,8 dogs were induced into final analysis.Bilateral lungs were normal on pre embolisation CT images.At 2h after embolisation,the left lungs had decreased opacification and the right lungs occurred different degree of ground glass opacification in 8 dogs.During reperfusion process,bilateral lungs appeared to different degree of ground glass opacification in 8 dogs,and did not recover until 4h after reperfusion.The contralateral lung did not show homogeneous change after reperfusion,while the embolized lungs showed the most serious damage at 3-4 h after reperfusion(n=7).Comprehensive evaluation showed the left lung lesions were slightly heavier than the right lung in 4 dogs,the right lung lesions slightly heavier than the left lung in other 4 dogs.Pathological examination showed the widened alveolar interval and hyperemia capillaries in bilateral lung tissues.Pathological findings agreed with CT imaging on severity of lung lesions.Continuous hypoxia and acid base disorders were represented during PIRI.But from embolisation to 4h after reperfusion,blood gas results had no statistically significant(P0.05),comprehensive analysis showed the pathophysiological changes were worst at 3 h after reperfusion.Conclusion Different degree of ground-glass opacification was main CT finding of PIRI in canine models,which will persist at least 4h after reperfusion.These CT findings were concord with pathophysiological changes,such as pulmonary capillary hyperemia,hypoxemia,and acid base disorders.
What problem does this paper attempt to address?