Reproducibility of liver position using active breathing control for primary hepatocellular carcinoma radiotherapy

ZHAO Jian-dong,JIANG Guoliang,XU Zhi-yong,ZHANG Xiao-jian,QIU Jian-jian
DOI: https://doi.org/10.3969/j.issn.1007-3639.2007.05.010
2007-01-01
Abstract:Background and purpose:Respiratory movement can increase planning target volume(PTV) of radiotherapy and result in the limitation of dose delivered to tumor.Active breathing control(ABC) provides a simple way to reduce respiratory motion.Immobilization of liver is an important premise to reduce the margin of planning target volume,but the reproducibility of liver position using ABC after deep inspiration is still unclear.The purpose of this study was to measure the reproducibility of liver position during radiotherapy.Methods:20 hepatocellular carcinoma patients were eligible for this study.16 of them had iodized oil deposited in the liver tumors.After breath training,the selected patients underwent CT simulation and radiotherapy with ABC.Intrabreath-hold liver stability was assessed using kV fluoroscopy during the breath-holding period.To measure intrafraction reproducibility of liver position relative to the vertebral bodies,patients were asked to inhale deeply and holding breath repeatedly for 5 times,then under simulator fluoroscope,the variation was obtained.Interfraction reproducibility of liver position in cranial-caudal direction was estimated by comparison of the variation of diaphragm between the digital reconstructive radiograph and weekly megavoltage verification images.Interfraction reproducibility of liver position in anterior-posterior and left-right direction was calculated by comparison of the variation of distance between the deposited iodized oil in the tumor and vertebral body through weekly X-graphs,respectively.Results:All patients were compatible with ABC technique and no one discontinued radiotherapy because of breath holding problem.Fluoroscopy revealed that the free breathing range of these patients was 1.6 cm(range 1.0-2.6 cm),and the average maximal liver motion during breathing-hold was 1.3 mm(range 0.0-2.9 mm).The average intrafraction and interfraction cranial-caudal reproducibility(standard deviation) of liver position relative to the vertebral bodies was 1.6 mm and 6.6 mm,in anterior-posterior direction the reproducibility was 0.9 mm and 4.2 mm,and in left-right direction that was 0.7 mm and 5.5 mm,respectively.Conclusions:The reproducibility of liver position is good in selected patients.However,interfracion reproducibility is worse than intrafraction reproducibility.It is rational to take the liver position reproducibility into account and apply image guidance during radiotherapy when considering the reduction of the planning target margin safely.
What problem does this paper attempt to address?