Application of active breathing control in 3-dimensional conformal radiation therapy for hepatocellular carcinoma: The feasibility and benefit

Jian-Dong Zhao,Zhi-Yong Xu,Ji Zhu,Jian-Jian Qiu,Wei-Gang Hu,Lan-Fei Cheng,Xiao-Jian Zhang,Guo-Liang Jiang
DOI: https://doi.org/10.1016/j.radonc.2007.12.006
IF: 6.901
2008-01-01
Radiotherapy and Oncology
Abstract:Background and purpose To investigate the feasibility and effectiveness of utilizing active breathing coordinator (ABC) in 3DCRT for HCC. Materials and methods A dosimetric comparison between the free-breathing (FB) plan and ABC plan in HCC 3DCRT was performed. Set-up errors and reproducibility of diaphragm position using ABC were measured, and patients’ acceptance was also recorded. Results From April 2005 to February 2007, 28 HCC were irradiated with ABC and they tolerated ABC well. The mean dose to normal liver was reduced from 16.9Gy in FB plan to 14.3Gy in ABC plan. PTV for ABC and FB plans were 529cm3 and 781cm3, respectively, and V23 were reduced from 45% to 30%. The predicted incidences of radiation-induced liver disease by Lyman model were 1% and 2.5%, respectively, in favor of ABC plan. The systematic and random errors for the ABC and FB plans were 1.2mm vs. 4.7mm, 1.6mm vs. 3.5mm, and 1.8mm vs. 2.7mm, respectively, in cranio-caudal, anterior-posterior, and left-right directions. The average intrafraction reproducibility of diaphragm position in cranio-caudal direction was 1.6mm, and the interfraction, 6.7mm. Conclusions The utilization of ABC in HCC 3DCRT is feasible, and can reduce liver irradiation.
What problem does this paper attempt to address?