Effects of filtration rates on performances of slow sand filter used for advanced domestic wastewater treatment

Cao Xiangsheng,Liu Jie,Meng Xuezheng,Wang Yue
DOI: https://doi.org/10.3969/j.issn.1674-5906.2010.08.031
2010-01-01
Abstract:To further improve reclaimed water qualities,a lab scale slow sand filter was used to polish the effluent of a secondary treatment wastewater reactor.Based on the determination of the turbidity、COD、color and total bacterial counts of influence and effluence,performances of the slow sand filter at different filtration rate(0.1 m/h、0.3 m/h、0.5 m/h) were evaluated.Results indicated that performances of the slow sand filter were nearly the same with the filtration rate at 0.1 m/h and 0.3 m/h.When the filtration rate was increased from 0.3 m/h to 0.5 m/h,performances of the slow sand filter decreased dramatically.During a period with the filtration rate at 0.1 m/h and 0.3 m/h,the average effluent of the turbidity、COD、color and total bacterial counts were 0.4 NTU,25.9 mg/L,14.9 °and 0.5×104 CFU/mL versus the removal rate 78.6%,36.0%,34.0% and 62.3% respectively.Recommended filtration rate for slow sand filters are below 0.3m/h in consider of getting high reclaimed water qualities.
What problem does this paper attempt to address?