Prevention of Galvanic Corrosion Between TC16 Titanium Alloy and 18ni Steel by Surface Modification

DENG Jian-qing,LIU Dao-xin,TANG Chang-bin,ZHANG Qing
2011-01-01
Abstract:TC16 titanium alloy was surface-modified by vacuum arc ion plating of TiN coating and micro-arc oxidation,while 18Ni steel was surface-modified by chemical oxidation.The level of galvanic corrosion,electrochemical impedance spectra and corroded morphology of the TC16 Ti alloy coupled with 18Ni steel was studied.Results indicate that there exists serious galvanic corrosion between TC16 Ti alloy and 18Ni steel,which can not be prevented by simply chemical oxidation treatment of 18Ni steel.By combining chemical oxidation of 18Ni steel with plating of TiN film on TC16 Ti alloy,the galvanic corrosion could be retarded to some extent.To effectively eliminate the galvanic corrosion,it was imperative to combine micro-arc oxidation treatment of TC16 Ti alloy with chemical oxidation treatment of 18Ni steel.
What problem does this paper attempt to address?