Optimization of heat exchange network in a wax oil hydrotreating unit on the basis of exergy analysis

Xiaoqiang Liang,Yongzhong Liu,Lixia Kang
DOI: https://doi.org/10.3969/j.issn.1001-4160.2011.12.013
2011-01-01
Abstract:For a wax oil hydroteating unit,exergy analysis of the heat exchange network was performed with thermodynamic parameters obtained from simulations using the software Aspen Plus.And the characteristics of energy consumption and utility targets were analyzed by pinch approach.On the basis of exergy losses and exergy efficiencies obtained,the optimal solution of the heat exchange network in the unit was proposed aiming at reduction of exergy losses and process changes.After revamped the total exergy loss of heat exchange network is reduced from 26115.5 kW to 15087.8 kW,decreased by 42.23%of the total exergy loss of the system.The analysis results and optimization solution could improve the quality of energy use of the wax oil hydrotreating unit,and could provide insights into the design of energy utilization and equipment improvement.
What problem does this paper attempt to address?