Study of Critical Flux in Flat-Sheet Membrane Bioreactors

Jian-hua SUN,Yi PAN,Sheng-san HUANG
DOI: https://doi.org/10.3969/j.issn.1009-6094.2007.04.011
2007-01-01
Applied Mechanics and Materials
Abstract:This paper is targeted as investigating and finding the impact of the measurement parameters in terms of the initial flux,its flux step increment and measuring intervals on the critical flux JC.JC is an important notion for controlling the membrane fouling.In this paper,we have measured it with the flux step-wise method.Our measuring results show that(1)the impact of initial flux on JC is not obvious when the initial flux is below JC,(2)when the step increment increases,the determining results of JC would decrease,and(3)the increase of the measurement interval would decrease the determining results of JC.According to what is said above,the measuring parameters of JC recommended can be listed below:the step increment is below 4 L/(m2·h),the measuring interval is 15-30 min while the value of the initial flux should be suitable.
What problem does this paper attempt to address?