Flow-injection Chemiluminescence Determination of Formaldehyde with a Bromate-Rhodamine 6G System.

Li Baoxin,Liu Meilin,Zhang Zhujun,Xu Chunli
DOI: https://doi.org/10.2116/analsci.19.1643
IF: 1.967
2003-01-01
Analytical Sciences
Abstract:In this paper, a novel flow-injection chemiluminescence (CL) system for the determination of formaldehyde is described. It is based on a strong enhance effect of formaldehyde on the weak CL emission of the reaction between potassium bromate and rhodamine 6G in a sulfuric acid medium. A possible mechanism for this CL reaction is proposed. A CL calibration graph was linear in the range of 0.8 - 200 µg l-1 and the detection limit was 0.3 µg l-1 (3σ). The relative standard deviation was less than 3% for 10 µg l-1 formaldehyde (n = 11). The method has been applied to determine formaldehyde in the air samples.
What problem does this paper attempt to address?