Study on a Modified Scheibel Extraction Tower

陈真生,袁慎峰,尹红,陈志荣
DOI: https://doi.org/10.3969/j.issn.1006-4184.2010.04.008
2010-01-01
Abstract:Scheibel extraction column is one of the available countercurrent agitated contactors. The main disadvantage of the Scheibel extraction column is the severe backmixing. In order to reduce the backmixing effect and provide efficient phase separation, a modified single stage Scheibel column was designed. Two sieve plates were installed at the two ends of the packed section and it can reduce the backmixing greatly. The factors of opening ratio, agitation speed and overall flow rates were studied in the modified Scheibel extraction tower by using propanol -water -heptane system. The optimized open porosity and operation parameters have been determined that the open porosity 10%, the agitation speed 100 r/min and the overall feed flow rate 6.0 mL/min. The extraction efficiency of the traditional Scheibel extraction tower and the modified Scheibel extraction tower were studied with the optimized opening ratio and operation parameters. The results demonstrated that the extraction efficiency of the modified Scheibel extraction tower was much better than that of the traditional one.
What problem does this paper attempt to address?