Study on performance of new type stack packed extraction column for furfural refining unit

Shenlin Zhu,Guangsheng Luo,Baoqing Zhang
1997-01-01
Abstract:The hydrodynamics and mass transfer experiments were carried out in a 0.1 m diameter extraction column with a new type of (FG) stack packing developed recently in our laboratory. The working systems used were n-butanol/succinic acid/water with low interfacial tension about 1.50 mN/m and 30% TBP (kerosene) /acetic acid/water with interfacial tension about 10.0 mN/m. Experimental results obtained indicate that (FG) stack packed extraction column is proved to possess high throughput capacity and excellent mass transfer efficiency. Replacing rotary discs with FG packings in tube furfural extraction tower was quite successful with significant economical benefits being claimed.