Performance of temperature and humidity independent control air-conditioning system in an office building
Kang Zhao,Xiao-Hua Liu,Tao Zhang,y w jiang
DOI: https://doi.org/10.1016/j.enbuild.2011.03.041
IF: 7.201
2011-01-01
Energy and Buildings
Abstract:The temperature and humidity independent control (THIC) system, which controls indoor temperature and moisture separately, may be an attractive alternative to existing conventional HVAC systems for its prominent improvement on the overall system performance and utilization of low grade energy resources. In order to verify the effectiveness of THIC system, a pilot project has been implemented in an office building in Shenzhen, China. In the system, liquid desiccant fresh air handling units driven by heat pumps are utilized to remove the entire latent load of outdoor air supplied for the whole building, and chilled water at the temperature of 17.5 °C from chiller is pumped and distributed into dry fan coil units and radiant panels to control indoor temperature. This paper presents the results of field test of the system, which shows that the system can provide a comfortable indoor environment even in very hot and humid weather. The COP of the entire THIC system can reach 4.0. According to the energy usage data recorded from the year 2009, the energy consumption of the THIC system in the tested office building was 32.2 kWh/(m 2 yr), which demonstrates magnificent energy-saving potential compared with the conventional air-conditioning system (around 49 kWh/(m 2 yr)). Keywords THIC (temperature and humidity independent control) Dehumidification Cooling Performance Air conditioning Nomenclature COP air coefficient of performance of the fresh air unit COP CH coefficient of performance of the chiller COP hum coefficient of performance of a set of humidity control subsystem COP HUM coefficient of performance of the humidity control subsystem COP TEMP coefficient of performance of the temperature control subsystem COP SYS coefficient of performance of the THIC system TC CT transport coefficient of the cooling tower TC CTP transport coefficient of the cooling water pump TC CWP transport coefficient of the chilled water pump TC fan transport coefficient of the fans in the humidity control subsystem TC FCU transport coefficient of indoor FCUs P air input power of the compressors and pumps inside the fresh air units P CH input power of the compressors of the chiller P CT input power of the cooling tower P CTP input power of the cooling water pump P CWP input power of the chilled water pump P fan input power of the fans in the humidity control subsystem P FCU input power of the fan coil units Q air cooling capacity of the fresh air unit Q CH cooling capacity of the temperature control subsystem 1 Introduction In the conventional HVAC system that removes moisture by condensation, air is cooled and dehumidified simultaneously. In most cases, sensible load of building covers the majority part of the whole cooling load while the latent load (moisture load) takes only a small part. However, as the required cooling source temperature of dehumidification is much lower than that of cooling, the chilled water temperature has to be reduced to meet the demand for condensation dehumidification. Moreover, the ratio of sensible load to latent load varies largely due to the changes of outdoor climate, number variance of indoor occupants, indoor equipments and lighting utilization mode and so on. Therefore, the indoor temperature and humidity, the two key parameters, can hardly be satisfied with condensation by the cooling coil only. In practice, the common reaction to the increased humidity is to reduce the set-point temperature and then re-condition the air after passing the cooling coil to the proper temperature, which results in a plenty of energy wastefulness [1] . To avoid the aforementioned problems, temperature and humidity independent control (THIC) air-conditioning system stands out as an appropriate pattern that temperature and humidity can be regulated independently with temperature control subsystem and humidity control subsystem respectively. Besides, the coil temperature for cooling in the temperature control subsystem can be considerably increased, e.g. from current 7 °C to 17 °C, so that improvement on the performance of chillers or even free cooling from ambient could be obtained. Many investigations have been carried out on the hybrid desiccant dehumidification and air-conditioning system [1–4] , which integrates liquid/solid desiccant units with a conventional cooling system to avoid excess cooling. Liquid desiccant units developed quickly in recent years, for its advantages of dehumidifying at a temperature higher than the air's dew-point to avoid reheat procedure in the system, and regenerating desiccant at a low temperature which can be driven by low-grade heat sources [5,6] . Many studies focusing on improving its performance with process optimization have been conducted in depth, such as Yadav [7] , DryKor Ltd. [8] , and Liu et al. [9] . Chen et al. [10] designed an independent dehumidification air-conditioning system with a hot water-driven liquid desiccant and a chiller that provides 18–21 °C chilled water for an office building in Beijing, which saved about 30% cooling cost compared with conventional system. The performance of a hybrid system tested by Ma et al. [11] was 44.5% higher than conventional vapor compression system at a latent load of 30% and this improving could be achieved by 73.8% at a 42% latent load. Besides, the specific research on the feasibility and performance of the hybrid system in hot and humid regions is promoted [12,13] . This paper will investigate the real operating performance of a THIC air-conditioning system operated in an office building located in Shenzhen, a modern metropolis in southern China of hot and humid climate. In this THIC system, the liquid desiccant fresh air handling units driven by heat pumps are employed to handle the outdoor air to remove the entire latent load and supply enough fresh air to the occupied spaces, and the high-temperature chiller that produces chilled water of 17.5 °C for the indoor terminal devices (radiant panels and dry fan coil units) is applied to control indoor temperature. The operating principle and performance test results of the THIC system will be shown in this paper, and suggestion for performance improvement will also be included. 2 Description of the THIC system in an office building The THIC system has been put into practice as a pilot project in an office building in Shenzhen, China. This system has been brought into operation in July 2008 and the basic information about the building and air-conditioning system goes as follows. 2.1 Basis information The 5-story office building, as shown in Fig. 1 , is located in Shenzhen, China, with total building area of 21,960 m 2 and the areas of 5940 m 2 , 5045 m 2 , 3876 m 2 , 3908 m 2 , 3191 m 2 for the 1st to 5th floor respectively. The main function of the 1st floor is restaurant, archive and carport, the 2nd to 4th floors are the office rooms, the 5th floor is the meeting room, and there is a vestibule vertically through up the 2nd to 4th floors in the north of the building. In the vestibule, curtain wall with ventilation shutters in the upper is applied on its north surface, as shown in Fig. 2 . The outdoor condition in Shenzhen is rather hot and humid all through the year as shown in Fig. 3 . The annual outdoor air relative humidity is about 80% and humidity ratio in summer is as high as 20 g/(kg dry air). The building requires cooling and dehumidification in a long period of time, and no heating and humidification requirement in winter. Therefore, how to handle the moisture efficiently is a key issue in such a subtropical area. 2.2 THIC air-conditioning system The THIC system serves from 1st to 4th floor with the net air-conditioning area of 13,180 m 2 (total area of 18,769 m 2 ), and the 5th floor is served by several stand-alone air conditioners so that is not within the scope of our discussion. The schematic of the THIC system is shown in Fig. 4 with the main devices’ parameters listed in Table 1 . The right side of Fig. 4 is the humidity control subsystem, including 9 liquid desiccant fresh air handling units that supply adequate dry fresh air into the occupied spaces. As the volume of the supplied fresh air is proportional to the number of people, the pollutants, CO 2 and latent heat produced by human bodies can be removed by fresh air. The schematic of the fresh air processors using liquid desiccant is illustrated in Fig. 5 (a) , which is composed of a two-stage total heat recovery device and a two-stage air handling device coupled with refrigeration cycles. Lithium bromide (LiBr) aqueous solution is employed as liquid desiccant in these air processors. The total heat recovery device is used to recover the energy from indoor exhaust air (return air) to decrease the energy consumption in the fresh air handling process. And in the heat pump driven air handling device, the diluted solution from the dehumidification modules is heated by the exhaust heat from the condenser and concentrated in the regeneration modules, then the hot concentrated solution is cooled by passing through the heat exchanger and evaporator before it enters the dehumidification modules, and lastly used to remove moisture from the fresh air. To make it clear, the air-handling processes are displayed in the air psychrometric chart in Fig. 5 (b) where the fresh air first passes the total heat recovery device to recovery the energy from the indoor exhaust air, and then flows into the dehumidification modules to be further dehumidified and cooled before it is supplied into the occupied spaces. In general, the COP of the liquid desiccant fresh air units (total heat removed from the fresh air divided by the power consumption of the heat pumps and solution pumps) can be as high as 5.0 with the following three main reasons: (1) the cooling capacity of the indoor exhaust air is fully exploited to remove heat from the fresh air by the total heat recovery device; (2) both the cooling capacity from evaporator and exhaust heat from condenser are utilized to enhance the air handling processes; and (3) the efficiency of the heat pump is significantly raised since the required evaporating temperature in this liquid desiccant device is much higher than that in the conventional condensing dehumidification system. Besides, as indicated in Fig. 5 (b), the supplied air temperature is lower than the indoor air temperature, so the liquid desiccant system can remove some sensible load of the building as well as the entire latent load. The left side of Fig. 4 is the temperature control subsystem that takes up the rest sensible load to control indoor temperature, including a high-temperature chiller, cooling tower, cooling water pump, chilled water pump, and indoor terminal devices (radiant panels and dry fan coil units). The high-temperature chiller is a centrifugal chiller with the rated COP of 8.3 (designed condition: the inlet and outlet temperature of the chilled water and cooling water are 20.5 °C/17.5 °C and 30.0 °C/35.0 °C respectively), which is much higher than the conventional chiller operating at the chilled water temperature of 12 °C/7 °C. As for indoor terminal devices, as shown in Fig. 6 , fan coil units (FCUs) operating in ‘dry condition’ are set up in the restaurant, archive and office regions which serve about 81% of the entire cooling load of the temperature control subsystem, while radiant floor and radiant ceiling panels are applied in vestibule and some office rooms which serve the rest 19%. In the previous sections, the whole THIC system layout has been introduced briefly. Particularly, stratified air conditioning, a key design principle of large space, is selected in the air-conditioning design of the vestibule as shown in Fig. 2 (b). Specifically, in the occupied zone (the height within 2 m), chilled water with temperature of 17.5 °C is pumped and distributed into radiant floor for cooling, and the handled dry fresh air and indoor exhaust air are supplied and expelled in the bottom and in the middle of the space respectively, which forms a “dry air layer” to protect the cold floor surface from condensation; in the higher space that far from occupied zone, solar radiation that enters through glass curtain wall is absorbed by the ornamental decorations in the higher space, and the heat is then carried away by natural ventilation through the shutters directly. The temperature control subsystem and humidity control subsystem can be operated separately according to ambient condition and indoor requirement. • The two subsystems operate together at hot and humid outdoor climate; • Only the humidity control subsystem operates at cold but humid ambient condition; • Outdoor air is directly introduced into occupied spaces after filtering when outdoor air is dry enough, such as 11 g/kg. 3 Performance test of the THIC system 3.1 Indoor thermal environment Fig. 7 shows the tested results of indoor temperatures, humidity ratios and CO 2 concentrations with the outdoor temperature and relative humidity of 34.9 °C and 61% respectively. As indicated by the figure, the THIC system could provide a comfortable indoor environment with suitable thermal condition and good indoor air quality. Fig. 8 depicts the tested temperatures and humidity ratios along the vertical direction in the vestibule. In the occupied zone (the height within 2 m), the temperature and humidity ratio were about 26 °C and 12 g/kg respectively which meet human thermal comfort well. Both the temperature and humidity ratio increased fast along the vertical direction, which reached about 30 °C and 20 g/kg respectively at the height of 10 m. And the peak temperature at upper space (over 7 m) occurred at noon, due to the strong solar radiation and high ambient temperature. According to the test results, the THIC system applied in large space is effective on energy-saving, which only keeps the occupied zone in comfort condition and forms apparent stratification of indoor temperature and humidity ratio along the vertical direction. Moreover, the natural ventilation from the shutters contributed to remove the absorbed heat of decorations to outdoor environment. 3.2 Energy efficiency of the THIC system The field test of the energy efficiency of the THIC system was conducted both under the partial load condition and very hot and humid outdoor condition. The former one is on May 27th, 2009, with ambient temperature of 29.3 °C and relative humidity of 79% (absolute humidity 20.3 g/kg), and the latter one is on July 16th, 2009, with ambient temperature of 34.9 °C and relative humidity of 61% (absolute humidity 21.6 g/kg). The measurement was divided into two parts: humidity control subsystem and temperature control subsystem. 3.2.1 Energy efficiency of humidity control subsystem The performances of the liquid desiccant fresh air units were tested one by one on May 27th, 2009, according to the measured flow rates, air inlet and outlet parameters through the processor and input power of compressors, solution pumps and fans. The tested results of seven fresh air units are summarized in Table 2 ; the other two processors are neglected due to the difficult of installing the measuring sensors. The east side processor of the 2nd floor is a typical example for the fresh air unit, and its specific operation information is shown in Table 3 . The fresh air flow rate was 5059 m 3 /h, the outdoor air parameter was 29.3 °C and 20.3 g/kg, and the supply air parameter was 17.1 °C and 6.2 g/kg. So the cooling capacity ( Q air ), calculated by energy balance equation, was 82.6 kW. The input power of compressors and solution pumps ( P air ) inside the processor was 17.8 kW, and the input power of the supply air and exhaust air fans ( P fan ) was 2.2 kW. Therefore, the performance of the fresh air unit ( COP air ), the transport coefficient of fans ( TC fan ) and the performance of the entire humidity handling process ( COP hum ), as shown in Eqs. (1)–(3) , are 4.7, 37.5 and 4.2 respectively. (1) C O P air = Q air P air (2) T C fan = Q air P fan (3) C O P hum = Q air P air + P fan As shown in Table 2 , the COP air of the tested seven fresh air units are in the range of 4.4–4.9, the TC fan of the fans are 35–40, and the COP hum of the entire humidity handling processes are 4.0–4.4. According to the test data of May 27th, 2009 and rated parameters of the fresh air units and fans, the calculated cooling capacity of the entire humidity control subsystem is 773.0 kW with total inside compressors and solution pumps input power of 166.9 kW and total fans input power of 20.0 kW, so the coefficient of performance of the humidity control subsystem ( COP HUM ), shown in Eq. (4) , is 4.1. (4) C O P HUM = ∑ Q air ∑ ( P air + P fan ) Similarly, on the basis of the test data of July 16th, 2009, the COP HUM under the design condition is 4.1, with the calculated cooling capacity of 915.0 kW, total inside compressors and solution pumps input power of 194.4 kW and total fans input power of 25.1 kW. 3.2.2 Energy efficiency of temperature control subsystem The performances of the chiller, cooling tower, cooling and chilled water pumps and indoor dry FCUs were measured, according to the measured flow rates, water inlet and outlet parameters through the chiller and input powers of above facilities. The tested results of each device are listed in Table 4 . According to the test data under the partial load condition (May 27th), the calculated cooling capacity of the temperature control subsystem ( Q CH ) is 446.1 kW with total input power of 120.8 kW, so the COP of the temperature control subsystem ( COP TEMP ), shown in Eq. (5) , is 3.7. As well, the COP TEMP under the very hot and humid condition (July 16th) is 4.1, with the calculated cooling capacity of 543.4 kW and total input power of 133.6 kW. (5) C O P TEMP = Q CH P CH + P CT + P CTP + P CWP + P FCU 3.2.3 Energy efficiency of the entire THIC system The entire load of the building is composed of the latent load and sensible load. The former is both the moisture introduced by fresh air and released by respiration and perspiration of occupants and indoor plants, and the latter is the caused by the ventilation, heat transfer, solar radiation, heat dissipation of devices and activity of occupants, etc., as illustrated in Fig. 9 . In the THIC system, processed outdoor air is used to remove the entire latent load and part of the sensible load, while cooling plant provides high temperature chilled water to remove the rest sensible load. By calculation, under the partial load condition, the humidity control subsystem removed 63% of entire cooling load with 61% environmental control energy consumption, and the temperature control subsystem removed the rest 37% load with the rest 39% energy consumption. Similar conclusion also can emerge from the test results in the very hot and humid outdoor condition. Calculated from the above tested data, the overall COP of the THIC system ( COP SYS ) under partial load and very hot and humid outdoor climate are 4.0 and 4.1 respectively, as shown in Eq. (6) . (6) C O P SYS = Q CH + ∑ Q air ( P CH + P CT + P CTP + P CWP + P FCU ) + ∑ ( P air + P fan ) Based on the test results of these two typical operating conditions, it is convinced that the THIC system in this office building has achieved a high efficiency with its total COP more than 4.0. For the conventional air-conditioning system, such as fan coil unit plus fresh air supply system or all air system, the measured average coefficient of performance of whole system is lower than 3.0 [14] . Therefore, there is a remarkable energy efficiency improvement of the THIC system comparing with the conventional system. 3.3 Energy consumption of the THIC system Energy consumption of the THIC system is measured by the power metering monitoring system. Fig. 10 shows the monthly power consumption of the system from 15th April, 2009 to 15th October, 2009 (apart from weekends and statutory holidays). The total energy consumption was 425 MWh during the air-conditioning season, and the humidity control subsystem occupied 61% of the total power consumption which was proportional to the ratio of cooling load that the humidity control subsystem took up. The energy consumption in unit building area and unit net air-conditioning area of the tested THIC system were 22.6 kWh/(m 2 yr) and 32.2 kWh/(m 2 yr) respectively. However, the average energy consumption levels of office building of the similar building envelope and occupant density during the same time in Shenzhen are around 42 kWh/(m 2 yr) and 49 kWh/(m 2 yr) respectively according to the investigated results by Zi [15] . Therefore, the THIC system in this office building achieves noticeable energy saving compared with the conventional air-conditioning system. The initial cost of THIC system is about 10–20% higher than conventional fan coil unit plus outdoor air process system, and the added cost can be recalled within about two years. 4 Discussion According to our knowledge, cooling air can be realized more easily than dehumidification by condensation, since the latter one requires lower temperature of cooling source than the former. However, the COP of the tested temperature control subsystem is lower than or equal to that of the humidity control subsystem in present THIC system. Thus, this section will focus on how to improve the performance of the temperature control subsystem. According to the performance of each component in the temperature control subsystem shown in Table 4 , three main improvements of the temperature control subsystem are recommended: (1) modifying the frequency of the chilled water pump; (2) improving the cooling tower performance by tightening the strap; and (3) improving the performance of FCUs under dry working condition. The first two methods can be easily realized in the building, while the third one depends on the improvement of new FCU products. 4.1 Improve the performance of chilled water pump As indicated in Fig. 9 (b) and Table 4 , the power consumption of the chilled water pump was near 60% of the chiller. It is because the variable-speed pump has operated at 50 Hz in the past that the chiller temperature difference of the inlet and outlet chilled water is only 1.6–1.8 °C, while the designed value is 3.0 °C. Therefore, the power consumption of the chilled water pump can be considerably cut down after reducing the chilled water flow rate by frequency regulation. For instance, the energy savings of the chilled water pump could be up to 40%, if the transport coefficient of chilled water pump ( TC CWP ) is increased from the current 14.6–18.5 to the empirical value of 25. 4.2 Improve the performance of cooling tower According to Table 4 , the transport efficient of cooling tower ( TC CT ) was near 140, which was lower than the empirical index of 200. Detailed performance test is then launched. For the cooling tower, the mass flow rate ratio of air to water was 0.55, with air flow rate of 99,620 kg/h and water flow rate of 180,000 kg/h, and the temperatures of inlet water, outlet water and outdoor air wet bulb were 35.6 °C, 32.9 °C and 28.3 °C respectively. Hence, the efficiency of the cooling tower (the temperature variance of the cooling water divided by the possible maximal temperature variance) was (35.6 − 32.9)/(35.6 − 28.3) = 37%. By field survey, the low air flow rate, which led to low efficiency of the cooling tower, was caused by the loose strap of fan. The energy consumption of the cooling tower in the entire air-conditioning system is relatively small, but it seriously influences the chiller performance by affecting the condensing temperature. The expected efficiency of the cooling tower can be higher than 55% if the air flow rate increases to about 180,000 kg/h, and thus the condensing temperature can decrease at least 2 °C. As a result, the COP of the chiller ( COP CH ) can be increased from current 8.5 to 9.3. 4.3 Improve the performance of FCU As the chilled water inlet temperature is higher than the indoor dew point temperature in this THIC system, fan coil units that operate under dry working condition are put into use in this building to remove large part of the sensible load of the building. At present, the configuration of the adopted dry FCUs is similar to the originally wet FCUs (with standard chilled water inlet temperature of 7 °C and transport coefficient of 50). However, the tested transport coefficient of the dry FCUs ( TC FCU ) was around 20, as shown in Table 4 . Factually, the configuration of dry FCUs should be rather different from wet FCUs, since condensing water no longer exists in dry FCUs, and some dry FCUs with new configuration have appeared with TC FCU close to 50. So there is a huge potential to improve the performance of dry FCU with the transport coefficient increased to around 40. The contribution of the above three improvements to the temperature control subsystem is summarized in Table 5 . And the expected COP TEMP and COP SYS can be increased to 4.8 and 4.4 respectively after these alterations. Therefore, the energy consumption of the altered temperature control subsystem can save 23% compared to present situation, and the entire THIC system can save 9% compared to its performance at present. 5 Conclusion The operating performance of the THIC system in an office building in Shenzhen is presented in this paper. Liquid desiccant fresh air units are used to supply dry fresh air to control indoor humidity, and chilled water with the temperature of 17.5 °C is pumped and distributed into radiant panels and dry fan coil units to control indoor temperature. The followings are the conclusions based on the tested results: (1) The THIC system can provide a comfortable indoor environment that indoor temperatures, humidity ratios as well as CO 2 concentrations are all within the comfortable ranges. (2) The COP of the entire THIC system can reach 4.0, with the COP of the temperature control subsystem and humidity control subsystem of 3.7–4.1 and 4.1 respectively. The energy consumption of the THIC system in the tested office building is 32.2 kWh/(m 2 yr) (net air-conditioning area), that is, the energy efficiency is much higher than that of the conventional air-conditioning system available in literature. (3) Possible improvements of the temperature control subsystem are provided, including modification on the chilled water pump, cooling tower and FCUs. Thus, the expected system COP can be further increased to 4.4, which can save 9% compared to present air-conditioning system. Acknowledgements The research described in this paper was supported by National Natural Science Foundation of China (No. 51006058 ) and the foundation for the author of National Excellent Doctoral Dissertation of China . The authors appreciate the valuable help from Mr. Qiang Bin and Mr. Yang Haibo in Shenzhen. References [1] D.G. Waugaman A. Kini C.F. Kettleborough A review of desiccant cooling systems Journal of Energy Resources Technology 115 1 1993 1 8 [2] T.A. Ameel K.G. Gee B.D. Wood Performance predictions of alternative, low cost absorbents for open-cycle absorption solar cooling Solar Energy 54 2 1995 65 73 [3] C.S.K. Ahmed P. Gandhisan A.A. Al-Farayedhi Simulation of a hybrid liquid desiccant based air-conditioning system Applied Thermal Engineering 17 2 1997 125 134 [4] C.H. Liang L.Z. Zhang L.X. Pei Independent air dehumidification with membrane-based total heat recovery: modeling and experimental validation Journal of Refrigeration 33 2 2010 398 408 [5] S. Patnaik T.G. Lenz G.O.G. Löf Performance studies for an experimental solar open-cycle liquid desiccant air dehumidification system Solar Energy 44 3 1990 123 135 [6] Y.G. Yin X.S. Zhang Z.Q. Chen Experimental study on dehumidifier and regenerator of liquid desiccant cooling air conditioning system Building and Environment 42 7 2007 2505 2511 [7] Y.K. Yadav Vapour-compression and liquid-desiccant hybrid solar space-conditioning system for energy conservation Renewable Energy 6 7 1995 719 723 [8] DryKor Ltd. Beyond air conditioning – our dry air is cool Illustrative Brochure 2001 DryKor Ltd. [9] X.H. Liu Z. Li Y. Jiang B.R. Lin Annual performance of liquid desiccant based independent humidity control HVAC system Applied Thermal Engineering 26 11–12 2006 1198 1207 [10] X.Y. Chen Z. Li Y. Jiang K.Y. Qu Field study on independent dehumidification air-conditioning system – II. Performance of the whole system ASHRAE Transactions 111 2 2005 277 284 [11] Q. Ma R.Z. Wang Y.J. Dai X.Q. Zhai Performance analysis on a hybrid air-conditioning system of a green building Energy and Buildings 38 5 2006 447 453 [12] J.L. Niu L.Z. Zhang H.G. Zuo Energy savings potential of chilled-ceiling combined with desiccant cooling in hot and humid climates Energy and Buildings 34 5 2002 487 495 [13] Y. Li K. Sumathy Y.J. Dai J.H. Zhong R.Z. Wang Experimental study on a hybrid desiccant dehumidification and air conditioning system Journal of Solar Energy Engineering 128 1 2006 77 82 [14] AQSIQ, SAC. GB/T 17981-2007 Economic Operation of Air Conditioning Systems 2008 China Standards Press Beijing [15] X.Q. Zi Diagnosis of energy efficiency and study on solutions for the air conditioning of the high-rise comprehensive office building in Shenzhen 2007 Master thesis, Chongqing University Chongqing
What problem does this paper attempt to address?
-
Performance test and analyses of temperature and humidity independent control air conditioning system in an office building in Shenzhen
Liu Shuanqiang,Liu Xiaohua,Jiang Yi,Liu Xin,Li Haixiang,Chen Xiaoyang,Qiang Bin,Yang Haibo
DOI: https://doi.org/10.3969/j.issn.1002-8501.2011.01.012
2011-01-01
Abstract:Presents the performance test of the main equipment of this temperature and humidity independent control air conditioning system(THICS).The test results show that the average COP of the liquid desiccant fresh air unit is about 5.4,and that of the high temperature chiller is about 8.9,while the EER of the water system is 5.1,the indoor air parameters of the typical room fit the design value very well,and the dew-point temperature of the indoor air is lower than the water supply temperature,the dry coil resulting no condensation.The annual average power consumption of the THICS is 34.3 kWh per square metre,about 69.3% of that of A-grade office building in Shenzhen.
-
Performance comparison of temperature and humidity independent control air-conditioning system with conventional system
tao zhang,xiaohua liu
DOI: https://doi.org/10.1177/0143624415610719
2016-01-01
Abstract:The energy consumption of centralized air-conditioning systems represents a large percentage of total building energy consumption in commercial buildings. The temperature and humidity independent control system, regulating indoor temperature and humidity separately through different approaches, is a feasible improvement to conventional systems. This paper focuses on the performance discrepancies between the temperature and humidity independent control systems and the conventional systems. A typical office building in Guangzhou is chosen for case study and energy performances of three temperature and humidity independent control systems with different outdoor air handling processes are investigated. Compared to the conventional system, energy efficiency ratio for the entire air-conditioning season of temperature and humidity independent control system I using condensing dehumidification is about 10% higher if the dry fan coil unit is adopted; of temperature and humidity independent control system II with high-temperature chilled water for precooling is about 16% higher, and energy efficiency improvement of temperature and humidity independent control system III with heat pump driven liquid desiccant air handling processor is about 22%. For other three cities in China, the energy saving ratio of temperature and humidity independent control system I is about 10%, about 15%-17% of temperature and humidity independent control system II and 20%-23% of temperature and humidity independent control system III.Practical application: THIC air-conditioning system is supposed to be an effective approach for energy saving in buildings. Chosen a typical office building as an example, this paper gives the energy performance discrepancies between the conventional system and the THIC systems for researchers and designers. Annual energy consumptions for different air-conditioning systems are compared, and the energy saving ratios of THIC systems are obtained. The research will be helpful for designing and constructing an energy efficient central air-conditioning system for buildings. In these typical cities or cities with similar climate, THIC system III with the highest energy efficiency is recommended just from the perspective of energy saving.
-
Analysis of a Hybrid System of Liquid Desiccant and CO2 Transcritical Cycles
Xiangyu Chen,Yijian He,Yi Wang,Guangming Chen
DOI: https://doi.org/10.1016/j.ijrefrig.2018.07.035
2019-01-01
Abstract:A novel hybrid system of liquid desiccant and CO2 transcritical cycles is proposed, where LiCl solutions are used as desiccants. Dissipated heat of the transcritical cycle is used to regenerate LiCl solutions, and the heat could be utilized efficiently with large temperature decrease. From insight of thermodynamics, model of the hybrid system is built. Based on the calculation results, temperature of the utilized heat could range from 120 degrees C to 50 degrees C. In addition, temperature and humidity independence control (THIC) could be conducted by the hybrid system. Under the same dehumidification capacity, its evaporation temperature could be obviously lifted. For the hybrid system, compression work (W) of the CO2 transcritical cycle could be reduced from 15% to 26%. Futher more, compared with cooling dehumidification at 7 degrees C by a conventional CO2 transcritical cycle, total power consumption of the hybrid system could be reduced by 13.7% at an evaporation temperature of 12 degrees C. More notablely, dehumidification efficiency of the hybrid system (COPhs') could be increased from 15% to 30% compared with dehumidification efficiency of cooling dehumidification by CO2 transcritical cycle (COPcs). (C) 2018 Elsevier Ltd and IIR. All rights reserved.
-
Performance of a temperature and humidity independent control air-conditioning system based on liquid desiccant for industrial environments
Bowen Guan,Xiaohua Liu,Qinling Zhang,Tao Zhang
DOI: https://doi.org/10.1016/j.enbuild.2020.109869
IF: 7.201
2020-01-01
Energy and Buildings
Abstract:Saving energy consumption of air-conditioning systems is becoming increasingly important in industrial buildings. In this study, measurements were conducted to reveal on-site performance of a full fresh air-conditioning system based on liquid desiccant applied in an industrial factory. Operating the system, temperature and humidity independent control (THIC) can be realized. The results reveal that the THIC system requires higher-temperature chilled water and no reheating process because of the adoption of a liquid desiccant dehumidifier, compared with the conventional vapor compression air-conditioning system. Therefore, a competitive system's coefficient of performance of 3.6 can be realized under the THIC system and an annual electricity-saving ratio of 23.3% can be achieved. In this system, the process air is divided into two parts, and the flow rate ratio of these two parts is discussed to further improve the system's performance. An optimal range of the ratio is determined in this study. When adjusting the ratio from the current 0.72 to 0.5, annual electricity consumption of the THIC system can be further saved by 5.4%. This study would provide valuable experience and reference for energy conservation of industrial air-conditioning systems.
-
Performance Study of a Constant Temperature and Humidity Air-Conditioning System with Temperature and Humidity Independent Control Device
X. J. Zhang,F. Xiao,S. Li
DOI: https://doi.org/10.1016/j.enbuild.2012.03.020
IF: 7.201
2012-01-01
Energy and Buildings
Abstract:To reduce the large energy penalty for constant temperature and humidity control in conventional air-conditioning systems, a novel temperature and humidity independent control (THIC) device is developed for typical cooling coils. The working principle of the THIC device is to adjust the chilled water flow rate in a cooling coil (CC) to maintain constant temperature and to adjust the apparatus dew point temperature of the CC to maintain constant humidity. A split-range control strategy is developed to control the cooling coil with the THIC device, the heater and the humidifier to achieve reliable control of indoor temperature and humidity while minimizing energy use.Control performance of the THIC device was tested in an existing constant temperature and humidity air conditioning system serving a storeroom in a museum. The field test shows that the indoor temperature and humidity were well controlled in the required range. Energy performance of the THIC was tested using simulation tests on TRNSYS platform. Seven testing cases with different typical load conditions were conducted. The energy performance of the THIC is compared with conventional air conditioning systems. The results show that the THIC device can achieve power saving of 30-50%. (C) 2012 Elsevier B.V. All rights reserved.
-
Analysis of a Hybrid System of Adiabatic Absorption two-stage Liquid Desiccant and CO2 Transcritical Cycles
Yi-Jian HE,Xiang-Yu CHEN,Guo-Bin HUANG,Guang-Ming CHEN
2018-01-01
Journal of Engineering Thermophysics
Abstract:A novel hybrid system of adiabatic absorption two-stage liquid desiccant and CO2 transcritical cycles is proposed,where LiCl solutions are used as desiccants. Dissipated heat of the transcritical cycle is used to regenerate LiCl solutions, and the heat could be utilized efficiently with large temperature decrease. From insight of thermodynamics, model of the hybrid system is built. Based on the calculation results, temperatures of the utilized heat could range from 120℃ to 50℃. In addition, temperature and humidity independence control could be conducted by the hybrid system and its evaporation temperatures could be obviously lifted. From the analysis, the dehumidification rate of the first dehumidifier increases when the moisture contents of ambient air increases. COP of the two-stage liquid desiccant cycle could be lifted when the temperature of LiCl solutions decreases and the concentration of LiCl solutions increases at the inlet of first dehumidifier. Available dissipated heat and evaporation temperature are closely related of the hybrid system. There is a critical evaporation temperature that makes the available dissipated heat to fully meet the need for regeneration of the hybrid system. Comparing with cooling dehumidification by a conventional CO2 transcritical cycle, under the same dehumidification capacity, COP of the transcritical cycle could be improved by 5.6% and compression work could be decreased by 29%.
-
Performance analysis on liquid desiccant based temperature and humidity independent control air-conditioning system
LIU Xiaohua,YI Xiaoqin,XIE Xiaoyun,CHANG Xiaomin
DOI: https://doi.org/10.3969/j.issn.2095-2783.2008.07.001
2008-01-01
Abstract:The operating principle of the temperature and humidity independent control (THIC) air-conditioning system is proposed in present study. The humidity control system using liquid desiccant is described in detail, and the performance is experimentally tested. The COP (coefficient of performance) of the liquid desiccant system decreases with increasing outdoor relative humidity ratio. The summer average COP of the liquid desiccant system which is cooled by cooling water and indoor exhaust air evaporative cooling is 0.93 and 1.19 respectively. The operating energy consumption is compared between the liquid desiccant based THIC system and the conventional air-conditioning system. The comparison results show that the THIC system saves about 50% power consumption and 20-30% operating cost, compared with the conventional air-conditioning system.
-
Operating practice of temperature and humidity independent control air conditioning system in an office building in Shenzhen
Yang Haibo,Liu Shuanqiang,Liu Xiaohua
DOI: https://doi.org/10.3969/j.issn.1002-8501.2009.05.031
2009-01-01
Abstract:Presents the operating and testing results of the system applied in this building,which show that the liquid desiccant fresh air handling unit can totally eliminate the space moisture load and the sensible load from the occupants and that the indoor temperature is about 25-26 ℃,the relative humidity is around 50%-60%,and the dry fan-coil unit can keep dry condition in the whole cooling period.In the project,the fresh air handling unit should be operated 1.5-2 hours in advance to eliminate the latent heat load and the high temperature water chiller should be operated 1-1.5 hours in advance to carry away the indoor sensible heat load.
-
Performance Analysis of a Temperature and Humidity Independent Control System with High Temperature Chilled Water Cooling and Condensing Heat Regenerating for Office Buildings
Shuo Liu,Xiaohua Liu,Hyusan Jang,Myoung-Souk Yeo
DOI: https://doi.org/10.1016/j.enconman.2024.118400
IF: 10.4
2024-01-01
Energy Conversion and Management
Abstract:Indoor humidity control is a crucial task in modern air conditioning systems. Conventional temperature and humidity independent control systems that use radiant cooling panels require dual temperature cooling sources and additional heating sources for reheating or regeneration. This study introduces a novel system that utilizes a central chiller to concurrently generate high temperature chilled water for cooling and hot water for regeneration. The system is analyzed in terms of the decoupling control effect and thermal balance, and is compared with the conventional system regarding energy consumption and energy efficiency. The results demonstrate that indoor humidity reset control improves the radiant cooling capacity and achieves a stable indoor thermal environment. The proposed thermal balance metric indicates that condensing heat can provide adequate regeneration heat within a broad range of indoor temperature and humidity setpoint conditions. Moreover, the thermal balance is particularly sensitive to the indoor humidity setpoints. Compared with the conventional system, the proposed system can reduce the chiller electricity consumption by 23.1 % due to the decreased cooling energy demand and dehumidification time. This energy-saving effect can reach up to 60 % when heat energy savings are considered. This study presents a viable solution for comfort air conditioning retrofits.
-
In Situ Performance of Independent Humidity Control Air-Conditioning System Driven by Heat Pumps
Weifeng Zhu,Zhongjian Li,Sheng Liu,Shuanqiang Liu,Yi Jiang
DOI: https://doi.org/10.1016/j.enbuild.2010.05.010
IF: 7.201
2010-01-01
Energy and Buildings
Abstract:A liquid desiccant based independent humidity control (IHC) air-conditioning system driven by heat pumps is presented in this paper. The system consists of a liquid desiccant fresh air processor and a high-temperature chilled water system. The operating principles of the fresh air processor and the whole system are presented in detail. Based on the in situ system installed in an ecological building of Shanghai Research Institute of Building Sciences (SRIBS), a performance investigation was performed in summer, 2007. The measurement results show that (1) the indoor temperature and humidity both are in the specified range; (2) the supply water temperature of the high-temperature refrigerator is higher than the corresponding indoor air dew point temperature, so no condensed water would be formed on the fan-coil unit (FCU) surface; and (3) the average coefficients of performances (COPs) of the fresh air processor and the high-temperature refrigerator are 6.24 and 4.38, respectively, and the average COP of the whole IHC system is 5.28.
-
Development of temperature and humidity independent control (THIC) air-conditioning systems in China - A review
Tao Zhang,Xiaohua Liu,Yi Jiang
DOI: https://doi.org/10.1016/j.rser.2013.09.017
IF: 16.799
2014-01-01
Renewable and Sustainable Energy Reviews
Abstract:A temperature and humidity independent control (THIC) system is a way to regulate indoor temperature and humidity separately through different approaches. Because of this distinction, THIC air-conditioning systems can satisfy the adjustment requirements of indoor temperature and humidity better than conventional systems can, and they show significant potential for energy conservation. In the past ten years, rapid improvements have been achieved in both theoretical research and the development of equipment related to THIC systems, and more and more applications are being put into use in non-residential buildings in China. This paper focuses on the development of THIC systems in China and reviews recent achievements and progress related to the main devices used for temperature and humidity control, including outdoor air handling dehumidification processors, sensible heat terminals, and high-temperature cooling sources. The energy performance of THIC systems is examined based on an analysis of established applications. Both the performance of key components and the energy consumption of entire systems indicate that THIC systems result in significant improvements in energy performance compared to conventional systems. Developmental trends and recommendations about design methodology, ways to improve the performance of handling devices, and feedback from applications of THIC systems are also discussed.
-
Optimum Control Strategy and Performance Simulation of a Constant Temperature and Humidity Air-conditioning System
Li Shen,Shen Jia,Zhang Xuejun,Zheng Youming
DOI: https://doi.org/10.3969/j.issn.0253-4339.2012.01.022
2012-01-01
Abstract:Due to the large energy compensation caused by the fixed dew point on the cooling coil(CC) in the conventional constant temperature and humidity air-conditioning system,a new system employing a temperature and humidity independent control device(THIC device) in the CC and a method of PID split-range control,is developed in this paper.Based on the experiment verification,the operation states and the energy saving effects of the system under different heat and moisture loads have been simulated by TRNSYS 16 software.The results show that under different working conditions,the system can automatically control air temperature and humidity independently with a high precision,by adjusting the mass flow rate and the temperature of the chilled water into the CC,and the output of the heater or the humidifier.In the design of such CC,the heat transfer area should be calculated under a higher inlet temperature of the chilled water(for example,12℃ instead of the usual 7℃).The system is energy-efficient with a rate of 30% under low temperature high humidity condition and about 50% under high temperature and low humidity condition,compared with the conventional system.
-
Performance Analysis on Temperature and Humidity Independent Control Air-conditioning System
Liu Xiaohua,Xie Xiaoyun,Liu Shuanqiang,Jiang Yi
2008-01-01
Abstract:The operating strategy of the temperature and humidity independent control(THIC) air-conditioning system is proposed in present study.Processed outdoor air is used to remove the entire latent load and control indoor humidity level and also improve indoor air quality.Cooling source with relative high temperature is used to remove the sensible load and control indoor temperature.The performances of the main components of the THIC system,including indoor terminal devices,outdoor air handler and high temperature chiller,are discussed in detail.The THIC system has large energy saving potential compared with conventional air-conditioning system.
-
Study on Independent Air Conditioning System Based on the Temperature and Humidity of Rotary Dehumidifier and Heat Pipe
Jiangbo Li,Haiwei Ji,Liu Chen
DOI: https://doi.org/10.1007/978-981-13-9524-6_11
2020-01-01
Abstract:For those areas with higher relative humidity in summer, the traditional air-conditioning system is difficult to meet the humidity requirements. A temperature and humidity independent control air-conditioning system based on rotary dehumidifier and heat pipe is proposed. The research on the working principle and thermodynamic calculation method of the system is carried out, and an office building in Shenzhen is taken as an example for thermodynamic calculation. Thermodynamic calculations were performed for Shenzhen, Beijing, Changsha, Wuhan Xi’an, and Guangzhou. The results indicate that the system can meet the requirements of indoor air supply better. Thermodynamic calculation indicates that the temperature and humidity independent control air-conditioning system based on rotary dehumidifier and heat pipe has the advantages of large dehumidification capacity and low energy consumption.
-
Annual performance of liquid desiccant based independent humidity control HVAC system
X LIU,Z LI,Y JIANG,B LIN
DOI: https://doi.org/10.1016/j.applthermaleng.2005.10.043
IF: 6.4
2006-01-01
Applied Thermal Engineering
Abstract:Based on a new type of sprayed liquid desiccant total heat recovery device, this paper presents the working principle of a liquid desiccant system combined refrigeration/heat grid system with the independent humidity control (IHC) strategy, in which the liquid desiccant system operates annually instead of only in the summer and removes the entire latent load and part of the sensible load. Electrical coefficient of performance (ECOP) and thermal coefficient of performance (TCOP) are adopted here to evaluate the performance of the IHC system. Reduced primary energy and operating cost differences of the IHC system and the conventional HVAC system are analyzed based on annual hour-by-hour simulation results for the Beijing climate. It is shown that (1) in summer, when the average latent load covers 30%, the average ECOP and TCOP of the IHC system are 6.7 and 6.8, primary energy consumption and operating cost are 78% and 75%, respectively, of the conventional HVAC system; and (2) in winter when average latent load covers 10%, the average TCOP of the IHC system is 1.34, primary energy consumption and operating cost are 62% and 57%, respectively, compared with the conventional system.
-
Application of a variable-speed ground-coupled liquid desiccant air-conditioner to multi-story office buildings in temperate regions
C. K. Lee,H. N. Lam
DOI: https://doi.org/10.1080/15435075.2014.910779
IF: 3.206
2014-05-16
International Journal of Green Energy
Abstract:A new variable-speed ground-coupled liquid desiccant air-conditioner was proposed and applied to a multi-storey office building in a temperate city of Kunming in China. Dynamic system simulations were performed to compare its performance with a constant-speed ground-source heat pump system. It was found that the use of the new system for a single-floor office reduced the annual unbalanced load to the ground heat exchanger borefield by nearly 70% together with a borehole depth reduction of up to 30%. For the case of a multi-storey office building, the number of floors served could be increased by 144% together with a reduction of CO2 emission by 43%. The results highlighted the merit of the new hybrid system with enhanced applicability when it was applied to a multi-storey office building in a temperate city.
energy & fuels,thermodynamics,green & sustainable science & technology
-
Investigation of a Compact Hybrid Liquid-Desiccant Air-Conditioning System for Return Air Dehumidification
Bowen Guan,Xiaohua Liu,Tao Zhang
DOI: https://doi.org/10.1016/j.buildenv.2020.107420
IF: 7.093
2021-01-01
Building and Environment
Abstract:In some automatic workshops, pharmaceutical warehouses, etc., there are control requirements for indoor air temperature and humidity, yet almost no occupants or no fresh air demand in the rooms. In this study, a hybrid liquid-desiccant air-conditioning (LDAC) system is proposed for the unoccupied rooms without fresh air demand. In the proposed system, the liquid dehumidifier and regenerator are cascaded, and the regeneration process is creatively moved to indoors. Two systems are selected as the reference systems, i.e., conventional vapor compression system (reference system I) and conventional LDAC system using outdoor air for regeneration (reference system II). The simulation results reveal that, under the typical summer condition in Guangzhou of China, the coefficients of performance (COPsys) of the proposed system, reference system I, and reference system II are 2.6, 1.8, and 2.3, respectively, when the air is dehumidified from 13.0 to 7.7 g/kg. Compared to the reference system I, the reheating process can be avoided, and higher-temperature chilled water at 16 degrees C can be used in the proposed system. Compared to the reference system II, using indoor air for regeneration helps to reduce the regeneration temperature. Thus, the proposed system demonstrates energy and space advantages than the reference systems.
-
Performance Analysis of a Combined Absorption Refrigeration-Liquid Desiccant Dehumidification THIC System Driven by Low-Grade Heat Source
Cong Xu,Jun Sui,Yuze Dai,Feng Liu,Hao Liu
DOI: https://doi.org/10.1007/s11630-020-1363-6
IF: 2.013
2020-08-14
Journal of Thermal Science
Abstract:Traditional condensing air-conditioning systems consume large amounts of energy in hot and humid areas, and it is difficult to achieve simultaneous control of temperature and humidity. A combined absorption refrigeration (AR) and liquid desiccant dehumidification (LDD) air-conditioning system based on cascade utilization of low-grade heat source is proposed. The system can realize independent control of temperature and humidity and carry out profound recovery of low-grade heat sources. Under the design conditions, the heat utilization rate ζ reaches 21.05%, which is 2.73 times that of the conventional absorption refrigeration reference system. A parametric sensitivity analysis is performed to optimize the system. The ζ increases from 9.79% to 18.55% and the coefficient of performance COPt increases from 0.33 to 0.35 with an increase in chilled water temperature from 7°C to 15°C. With an increase in regenerant solution temperature from 60°C to 70°C, the ζ achieves the optimal value of 21.05% at 68°C. ζ decreases from 21.05% to 15.05% as the concentration of the regenerant solution increases from 36% to 40%. Under variable environmental temperature and humidity, the ζ of the proposed system changes within a small range and stays much higher than that of the reference system with the same quality heat source, which indicates that the proposed system has a better adaptability to changing environmental parameters.
engineering, mechanical,thermodynamics
-
Simulation and Experimental Analysis of A Fresh Air-Handling Unit with Liquid Desiccant Sensible and Latent Heat Recovery
Xiaoyun Xie,Yi Jiang,Yidan Tang,Xiaoqin Yi,Shuanqiang Liu
DOI: https://doi.org/10.1007/s12273-008-8210-0
IF: 4.0083
2008-01-01
Building Simulation
Abstract:This article introduces a liquid desiccant fresh air processor. Its driving force is low-grade heat (heat obtained from 65 – 75°C hot water). Inside the processor, the air is dehumidified by the evaporative cooling energy of the indoor exhaust air. A four-stage structure is used to increase the efficiency of the combined sensible and latent heat recovery from the exhaust air. A mathematical model of the fresh air processor was set up using Simulink®. A liquid desiccant fresh air processor was constructed and tested for outside air conditions of 29.1 – 33.6°C, 13.7 – 16.7g/kg humidity ratio, and supply air conditions of 23.6 – 24.2°C, 7.4 – 8.6g/kg humidity ratio. The average measured COP f was 1.6 (cold production divided by latent heat removed) for the range of conditions tested. The corresponding average COP sys of the system including the regenerator was 1.3 (cold production divided by heat input). The detailed operating parameters of each part of the test unit were also measured. The test data was compared with the simulated performance. The characteristic coefficients (such as the volumetric mass transfer coefficient of the air-water evaporative cooling module, etc.) in the mathematical model were modified to calibrate the model output to the measured data. The calibrated simulation model was used to investigate the control strategy of the fresh air processor. The flow rate of the strong solution into the unit and the number of operation stages may be controlled separately or together to meet different indoor air requirements at different outdoor conditions. The hot water driven liquid desiccant air conditioning system was compared with a typical vapor compression system with an average COP of 4.5; the pump and fan power of the proposed system was 40% of the combined chiller, pump, and fan consumption. We achieved savings of over 30% of the power consumption compared with the traditional system under the designed outdoor air conditions.
-
Experimental Performance Investigation on a Desiccant-Assisted Two-Stage Evaporative Cooling System in Hot and Humid Areas
Yanling Zhang,Yi Chen,Hongxing Yang,Hao Zhang,Chun Wah Leung
DOI: https://doi.org/10.1016/j.apenergy.2024.124704
IF: 11.2
2025-01-01
Applied Energy
Abstract:The escalating demand for energy-efficient and eco-friendly air conditioning systems in buildings has spurred the development of comfortable, efficient, and cost-effective air handling system configurations. Desiccant cooling has shown a higher coefficient of performance (COP) compared to traditional vapor compression refrigeration (MVCR) systems. However, current desiccant cooling facilities struggle to decouple and efficiently handle indoor heat and moisture loads. The complexity of these facilities has kept intricate cooling systems remaining theoretical, requiring simplification and experimental investigation. This paper presents an experimental study on a compact, two-stage evaporative cooling system assisted by a liquid desiccant. A key innovation of this system is the inclusion of a two-stage heat exchanger that adeptly manages the decoupling of indoor heat and moisture loads under challenging high-temperature and high-humidity conditions. Performance analysis was conducted experimentally under three hot and humid climatic conditions using an optimized operating parameter scheme. Starting from an initial condition of 36.22 degrees C and a humidity ratio of 0.028 kg/kg, the proposed system achieves COP values ranging from 11.3 to 18.4 without compromising indoor comfort or facility compactness. Under high heat and high humidity conditions, the optimized system extracts 20 % of the product air as the secondary air source. It can reach a minimum supply air temperature of 18.44 degrees C, achieved under optimized conditions of low wind speed (1.0 m/s), high desiccant concentration (35 %), and substantial desiccant flow (0.09 kg/s). Experimental studies of this new system provide the possibility of achieving high efficiency in air handling over a wide range of temperatures and humidity.