Experimental Study on Failure Mechanism of the Apron Slabs of an Inverted Arch Plunge Cushion Pool under High Water Head and Large Discharge

邓永锋,孙建,郝秀玲,张发茂,张春财
2010-01-01
Abstract:Experiment was conducted to study the overall and partial failure mechanisms of the apron slabs of an inverted arch plunge pool under high water head and large discharge for the hydraulic design of a high arch dam project under construction.Various factors are tested in this study,such as water head,discharge,the opening of contraction joints between slabs,the number of movable slabs on the arch ring,boundary condition of movable and fixed arch-abutments,and their combinations in the extreme case that all the water seals between slabs are out of function.Results show the three most important factors of great uplift force acting on the apron slabs,constraint conditions on the arch abutments and opening of slab joint.Local instability or slab sliding away from the arch ring is caused by the increasing vibratory displacements of slabs and the decreasing axial restriction between slabs,a result of the widened or accumulatively widened joint openings and the excessive numebr of movable slabs on the ring.The global instability or losing axial restriction of slabs on each other is a consequence of a small displacement of the arch abutment.In a practical design of inverted arch plunge pool,the stability of arch abutments must be totally guaranteed,and the slab joint opening,particularly the right-and-left joints,should be controlled within an appropriate extent.
What problem does this paper attempt to address?