Experimental Study on Axial Forces Between Slabs of Inverted Arch Plunge Cushion Pool under Action of Uplift Forces

刘艳丽,杨丽萍,孙建,张金明,张春财
2013-01-01
Abstract:An experiment was conducted to study the axial forces on the bottom slabs under action of uplift forces for an inverted arch plunge pool that works under high water heads and large discharges similar to the Xiluodu high arch dam,considering two cases of failure in anchoring structure of a single slab and nine slabs on the arch ring.Results reveal the mechanism of axial forces generation and transmission,i.e.after the uplift forces induce shifting and locking of certain slabs,constraint axial forces are created on their adjacent slabs and these forces are transferred in turn to the next neighboring slabs,until to the arch abutments eventually.The distribution of such axial forces can be divided into a region of strong impacting vibrations and two regions of upriver and downriver strong vibrations.The former region is featured with small time-average axial forces,large instantaneous axial forces and strong slab vibrations,so the slabs is locked only in a short time,forming a instantaneous arch.But the latter regions are featured with large instantaneous and time-average axial forces and weaker slab vibrations,so the locked slabs can form a local arch for longer time.In all these three regions,the dominant frequencies of slab vibrations fall within a narrow range of low frequency below 0.2 Hz.Thus,when an inverted arch plunge pool is in operation,to control the magnitude of its axial forces within a suitable range,the radial displacement of its bottom slabs and the number of locked slabs should be reduced.
What problem does this paper attempt to address?