Application of shear wave elastograpgy in measurement of muscle tension and localization of Zusanli acupoint in human being

XU Fang,XIAO Hu-sheng,XU Zhi-zhang,ZHANG Ai-hong,REN Ya-juan,YIN Hao-qiang,GAO Dong-wen,PENG Xin,ZHOU Liang-mei
DOI: https://doi.org/10.3969/j.issn.1008-617X.2012.02.002
2012-01-01
Abstract:Objective To evaluate the value of shear-wave elastograpgy(SWE ) in the measurement of muscle tension of Zusanli(ST36 ) acupoint and high-frequency ultrasound in the localization of Zusanli acupoint.Methods The muscle tension of Zusanli acupoint was measured and recorded by a real-time SWE instrument(AixPlorer ) produced by France Supersonic Imagine before acupuncture,during acupuncture and during electroacupuncture.The results were compared.The Zusanli acupoint was pinpointed by high-frequency ultrasound according to anatomy atlas of meridian acupoints section.Results The average value of Young's modulus in Zusanli acupoint before acupuncture,during acupuncture and during electroacupuncture was(12.61±6.27 ) kPa,(24.00±11.94) kPa,and(111.48±52.81 ) kPa when the diameter of sampling was 3 mm in the quantity analysis system of SWE. The average value of Young's modulus in Zusanli acupoint before acupuncture,during acupuncture and during electroacupuncture was(15.85±5.93 ) kPa,(25.72±13.63 ) kPa,and(84.84±49.60 ) kPa when the diameter of sample was 8 mm.The average value of Young's modulus in the spots of acupoint Zusanli during the ahead of acupuncture,acupuncture and electroacupuncture was(17.75±6.72 ) kPa,(24.92±11.50 ) kPa,and(70.75±42.20 ) kPa when the diameter of sampling was 12 mm.The average value of Young's modulus in Zusanli acupoint during acupuncture was significantly higher than that before acupuncture(P<0.01 ) when the diameter of sampling was 3 mm,8 mm and 12 mm.The average value of Young's modulus in Zusanli acupoint during electroacupuncture and during electroacupuncture was significantly higher than that before acupuncture(P<0.01 ) when the diameter of sampling was 3 mm,8 mm and 12 mm.Conclusion The method by high-frequency ultrasound of localization meridian acupoints different from meridian acupoints section in corpse is accurate,direct,dynamic,simple and cheap,which overcomes the limitation of CT and MRI.The muscular tensity of Zusanli acupoint measured by SWE during acupuncture and electroacupuncture is one of the new reference indices that can be used forjudging the degree of qi arrival.
What problem does this paper attempt to address?