Dynamic Measurement of the Elastic Modulus of the Contractive Biceps Brachii by Shear-Wave Elastography and the Discussion on Its Physiological Significance

XIAO Hu-sheng,REN Ya-juan,XU Zhi-zhang,ZHANG Ai-hong,XU Fang,YIN Hao-qiang,GAO Dong-wen,XU Yi-jun,WANG Qi
DOI: https://doi.org/10.3969/j.issn.1008-617x.2012.02.001
2012-01-01
Abstract:Objective To explore the physiological significance of the the correlation curve of Young' s modulus versus time by continuous determination of Young' s modulus of the biceps brachii muscle belly in the muscle contraction process.Methods A shear-wave elastography(SWE)(AixPlorer model,Supersonic Imagine,Aix en Provence,France) coupled with a linear array transducer(4-15 MHz) was used.The ultrasound probe was placed in the cross-section of the biceps brachii muscle belly,then the scanner was set at the SWE mode.The tissue elasticity map of the biceps brachii was recorded during the muscle contraction process, then the record was replayed at movie mode.The Q-BOX quantitative analysis system was used and the diameters of sampling area were set as 3,8 and 10 mm respectively like a concentric circle(similar to the target ring).Finally,Young' s modulus was measured once every 10 frames.Young' s modulus was totally measured 20 times,with the first 10 times detected before the muscle contraction and the final 10 times detected during the muscle contraction process.The correlation curve of Young' s modulus versus time by continuous determination of Young' s modulus of the biceps brachii muscle belly in the muscle contraction process was protracted according to the measured values of all the 20 times.Results When the diameter of Q-BOX sampling area was set as 3 mm,the average Yang' s modulus before muscle contraction was(31.48±2.25)kPa and during the muscle contraction process was (83.10±23.46 ) kPa;When the diameter of Q-BOX sampling area was set as 8 mm,the average Yang' s modulus before muscle contraction was(34.19±2.26) kPa and during the muscle contraction process was(94.41±27.73) kPa;When the diameter of Q-BOX sampling area was set as 13mm,the average Yang' s modulus before muscle contraction was(36.96±2.35)kPa and during the muscle contraction process was(103.21±36.96 ) kPa.The correlation curve of Young' s modulus versus time showed that during the contraction process of biceps brachii muscle belly,the measured values of Young' s modulus gradually increased from minimum to maximum as a rising slope.Conclusion The average Young' s modulus before and during the contraction process of biceps brachii muscle belly are different.The SWE has adequate sensitivity to fulfill the real-time detection of Young' s modulus during the contraction process of biceps muscle belly.During the contraction process of biceps brachii muscle belly,the correlation curve of Young1 s modulus versus time is in accordance with the skeletal muscle contraction characteristics described at the molecular level.
What problem does this paper attempt to address?