The Observation of Zusanli Tension Before and after Acupuncture and in Different Muscular Tension by Application of Shear-Wave Elasto-Sonography Technology

任亚娟,徐芳,徐智章,张爱宏,肖沪生,银浩强,高东雯,俞成杰
DOI: https://doi.org/10.3969/j.issn.1672-0512.2013.02.001
2013-01-01
Abstract:Objective: To explore the significance of using shear-wave elasto-sonograpgy in the measurement of muscular tensity of Zusanli under different muscular tension condition and explore the significance of detecting Zusanli tension before and after acupuncture by shear-wave elasto-sonograpgy.Methods:The muscular tensity of Zusanli was measured and recorded by a real-time quantitive shear-wave elasto-sonograpgy instrument(AixPlorer)which was produced by France Supersonic company.The muscular tension of Zusanli was detected when the subject took different postures(dorsal decubitus,stance and musculartone)with the L4-15 linear array probe applied at Zusanli acupoint section.After that,the muscular tensity of Zusanli of 30 subjects was measured before acupuncture,during acupuncture and during electroacupuncture then results were compared.The spots of point Zusanli were pinpointed by high-frequency ultrasound according to anatomy atlas of meridian acupoints section.Results:The average value of Young's modulus in the spots of point Zusanli with supine position was(14.01±4.38)kPa、with stand position was(87.24±30.33)kPa,with active contractive muscle was(87.42±12.12)kPa when the diameter of sample was 3mm in the Quantity analysis system of Shear-wave elasto-sonograpgy.The average value of Young's modulus in the spots of point Zusanli at decubitus posture during the ahead of acupuncture,acupuncture and electroacupuncture was(12.61±6.27)kPa,(24.00±11.94)kPa,(111.48±52.81)kPa when the diameter of sample was 3mm in the Quantity analysis system of Shear wave elastograpgy.The average value of Young's modulus in the spots of point Zusanli during acupuncture was significantly higher than that of the group during the ahead of acupuncture,(P0.01)when the diameter of sample was 3mm.The average value of Young's modulus in the spots of point Zusanli during electroacupuncture was significantly higher than that of the group during acupuncture,(P0.01)when the diameter of sample was 3mm.Conclusions:Shear-wave elasto-sonography can be used in quantitative analysis of muscular tension and the tension of the acupuncture points will be significantly affected by different degree of muscle tension.The muscular tension can be quantitatively detected by Shear-wave elasto-sonography.Using of Shear-wave elasto-sonography can provide a new method and new idea for quantitative analysis and objective assessment for muscular tension of a variety of diseases.The non-invasive measurement of muscular tension of Zusanli by Shear-wave elasto-sonograpgy during acupuncture and electroacupuncture provides a new way for the study of De Qi in TCM acupuncture and the study should be applied with the supine position in all the muscle relaxation state.
What problem does this paper attempt to address?