Transcatheter occlusion of large atrial septal defect with edge-insufficiency

Yingzhang CHENG,Qinghua WU,Xiaoshu CHENG,Yanna LIU,Kui HONG,Zhengzhang LI,Juxian LI,Yanqing WU
DOI: https://doi.org/10.3969/j.issn.1001-1439.2008.10.011
2008-01-01
Journal of Clinical Cardiology
Abstract:Objective:To evaluate the safety and efficacy of the transcatheter occlusion of secundum type atrial septal defect size from 36 mm to 42 mm with edge-insufficiency(0-4 mm and without utility support edge) by homemade septal occluder.Method:Thirty six cases with large(36 to 42 mm) secundum type atrial septal defects were confirmed by transthoracic and transesophageal color Doppler echocardiography.All of them were confirmed that edge-insufficiency were from 0 to 4 mm at least one side and without utility support edge.Following guideline,transcatheter closure of atrial septal defects were monitored by transthoracic or transesophageal color Doppler echocardiography and X-ray fluoroscopy.According to the edge-insufficiency conditions,defects were divided into six types: atrium-roof edge-insufficiency,mitral valve edge-insufficiency,aortic edge-insufficiency,posterior(aortic contralateral edge) edge-insufficiency,inferior vena cava edge-insufficiency and complex types.Then we selected adapted septal occluder to occlude.Result:① Of 36 cases,18 cases were 36 mm defect,8 cases were 37 mm,4 cases were 38 mm,3 cases were 39 mm,1 case was 40 mm,1 case was 41 mm and 1 case was 42 mm.② There were 4 cases of simple atrium-roof edge-insufficiency type,3 cases of simple mitral valve edge-insufficiency type,15 cases of simple aortic edge-insufficiency type,5 cases of simple posterior edge-insufficiency type,4 cases of simple inferior vena cava edge-insufficiency type,2 cases of aortic edge-insufficiency with inferior vena cava type and 3 cases of posterior edge-insufficiency type with inferior vena cava type.③ 32 cases of 36 cases were occluded successfully,successful rate of 88.89%,and 4 cases were unsuccessful,whose defect sizes were 36 mm,37mm,39 mm and 41 mm.According to the type,they were 3 cases of posterior with inferior vena cava edge-insufficiency,and 1 case of aortic with inferior vena cava edge-insufficiency.There was no complication in all patients.④ Occluders size were 38 mm in 26 cases,40 mm in 6 cases.Conclusion:Large(36-42 mm) secundum type atrial septal defects with edge-insufficiency can be occluded with interventional treatment.Homemade interventional occluders for large atrial septal defects are safe,effective,fewer complications,and low-cost,and can be used as preferred option in patients with occluded indications.
What problem does this paper attempt to address?