Simultaneous removal of aqueous Cr(Ⅵ) and phenol by corona discharge plasma

WANG Jinyu,SUN Yabing,MIAO Hong,XU Jianhua,FENG Jingwei
DOI: https://doi.org/10.13671/j.hjkxxb.2012.10.016
2012-01-01
Abstract:Corona discharge plasma was adopted to remove Cr(Ⅵ) and phenol in aqueous solution simultaneously.The effects of output power intensity,airflow rate,initial pH value,initial concentration and the ratio of Cr(Ⅵ) and phenol on the removal rates of aqueous Cr(Ⅵ) and phenol were investigated.The experimental results showed that high removal rates for aqueous Cr(Ⅵ) and phenol were observed,and 98.8% of Cr(Ⅵ) and 99.9% of phenol could be removed after 40 min with initial concentration 30 mg · L-1,initial pH value 2.1,airflow rate 0.05 m3 · h-1,initial conductivity 2.26 mS · m-1,discharge distance 6 mm and output power intensity 60 W.The experimental results confirmed that the removal efficiency of Cr(Ⅵ) was improved in the presence of phenol,but no additional effect for Cr(Ⅵ) removal was observed with the excessive amount of phenol.The existence of Cr(Ⅵ) had no effect on the removal efficiency of phenol.
What problem does this paper attempt to address?