A Quantitatively Pilot Study of Pulmonary Perfusion of Healthy People by Using 320-Detector Row Dynamic Volumetric CT
方进,毛家骥,梁敏杰,邓达标,胡钰,邹亚妮,李红林,蔡湘怡,周全
DOI: https://doi.org/10.13437/j.cnki.jcr.2016.10.036
2016-01-01
Abstract:Objective To study the ratio changes of systemic circulation and pulmonary circulation blood flow of the lungs in normal subjects,and compare the perfusion parameters among the normal in a different district. This is done to explore the feasibility and superiority of low-dose CT pulmonary perfusion by using the 320-detector row dynamic volumetric CT. Methods A total of 20 patiens in our hospital were collected from 2014 May to 2015 January. A Toshiba 320-detector row dynamic volumetric CT scanner( Aquilion One,Japan Toshiba medical device company) was used for lung volumetric scan in this study and with scanning parameters of 80 k V,70 m A current,and AIDR image reconstruction. The volume data was processed with the image post-processing software,and 4 time-density curves were produced,meanwhile the time to peak( TTP) is recorded. In order to evaluate from the gravitational( ventral,middle,dorsal) and non-gravitational direction( upper,middle and lower),the regions of interest in the various places were selected,and finally the lung parenchyma pseudo color perfusion images were displayed,which revealed the pulmonary artery flow( PAF),bronchial artery flow( BAF) and perfusion index[PI = PAF /( PAF + BAF) ]. We selected each region to measure at three consecutive levels and respectively achieved average perfusion parameters( PAF,BAF,PI) in every region. The statistical analyses of the data obtained from above were performed to analyze the difference in perfusion of various regions in normal subjects from the gravitational and non-gravitational direction with the single-factor analysis of variance. Results The total radiation dose was 4. 02 m Sv per subject. There was visible difference in PAF in the direction of gravity in the normal lung parenchyma group( F = 13. 29,P = 0. 00),PAF was 123. 2 ± 32. 9,137. 1 ± 33. 6,158. 5 ± 38. 7 ml·min- 1·100ml- 1from ventral to dorsal respectively and there was a significant statistical difference between each other,but there was no obvious difference in BAF and PI. In the non-gravitational direction,PAF,BAF and PI all had a marked difference in total( P <0. 05),but if compared with each other,it displayed a significant statistical difference only between the upper and lower region( P < 0. 05) Conclusion The low dose of lung perfusion scanning by using 320-detector row dynamic volumetric CT scan can quantitatively assess the proportion of pulmonary and systemic circulation in normal subjects. About 98. 76%normal pulmonary parenchyma was supplied by the pulmonary artery,bronchial arterial blood was a very small percentage,and PAF and BAF in gravitational and non-gravitational direction were influenced by gravity and blood flow distribution.