Study on the Determination of Cefaclor in Human Plasma

TANG Cheng,TIAN Jie,HUANG Min
DOI: https://doi.org/10.3321/j.issn:1001-5213.2006.11.012
2006-01-01
Abstract:OBJECTIVE To improve stability of cefaclor in human plasma,so as to ensure its accuracy of plasma-concentration data.METHODS Cefaclor was separated and determined with a HPLC system.Stability of Cefaclor sample in plasma in variety of condition was observed after adding KH_(2)PO_(4) to human plasma.RESULTS Extract recovery was(81.9%)~(87.1%).Method recovery was(99.9%)~(105.2%).Within-day Variation was(0.9%)~(4.9%);between-day was(1.0%)~(7.0%).Irrelevance plasma standing in room temperature for 4 h was(0.8%)~(2.9%);Freezing thawing three times was(1.0%)~(4.1%);Plasma freezing reservation for 35 d was(4.5%)~(0.03%);Standing of extract in room temperature for 22 h was(7.1%)~(4.0%).CONCLUSION Each datum accords with the requirement of human bioavailability and pharmacokinetics study.