Study of Pharmacokinetics and LC-MS/MS Method of Blood Concentration of Clarithromycin

CAO Shi-lei,HUANG Ping,CHEN Jun,JIANG Xin-guo,WANG Xiao-lin,CHEN Chun-lin
DOI: https://doi.org/10.3969/j.issn.1007-4406.2007.02.008
2007-01-01
Abstract:AIM To develop a LC-MS/MS method to determine clarithromycin in human plasma.METHODS The tested drug and internal standard clarithromycin were extracted from plasma samples and chromatographed on a C18 column.The mobile phase consisted of methanol-water(1%formic acid)-acetonitrile(80∶10∶10,V/V/V).Detection was performed on a triple quadrupole tandem mass spectrometer via electrospray ionization source in the positive mode.RESULTS The linear calibration curves were obtained in the concentration range of 10-2 500 μg·L-1.The intra-and inter-run precisions were lower than 3.5% in terms of relative standard deviation.tmax,ρmax,t12,AUC0→t and AUC0→∞ values were found to be(1.95±0.71) h,(949±399) μg·L-1,(4.79±0.84) h,(5 600±1 753) μg·h·L-1,(5 766±1 776) μg·h·L-1,respectively after a single oral dose of 250 mg clarithromycin capsule to 18 volunteers.CONCLUSION This method is successful in the evaluation of pharmacokinetic profiles of clarithromycin capsule in huaman plasma.