Experimental Investigation on Extending Load Range of Diesel HCCI Engine by Internal EGR and Boost

GUI Yong,SUN You-cheng,XU Min,DENG Kang-yao,SHI Lei
DOI: https://doi.org/10.3969/j.issn.1001-2222.2012.02.008
2012-01-01
Abstract:On a single cylinder diesel engine,the load characteristics between traditional combustion and HCCI combustion were compared,the injection timing of HCCI was optimized and the influences of internal EGR rate and boost pressure on HCCI combustion load range and emissions were analyzed.The results show that the best injection timing of HCCI mode with the negative valve overlap at 1 500 r/min is 370°BTDC.The-30° valve overlap can guarantee lower NOx emission and better load range.The increase of boost pressure extends the upper load limit of HCCI combustion and is beneficial to the combustion stability of lower load limit.Improving the boost pressure on 0.18 MPa,the upper load limit increases from 0.594 MPa to 0.723 MPa,but lower load limit also increases,which gives worse CO emission,smoke and fuel economy.
What problem does this paper attempt to address?