Relationship Between the UV Corona Pulses and the Corona Current Pulses

WANG Can-lin,LIAO Yong-li,WANG Li-ming,WANG Ke
DOI: https://doi.org/10.3969/j.issn.1003-6520.2007.07.020
2007-01-01
Abstract:The problem of contact detecting method is that the intensive environment disturbances make the results incorrect.The UV corona detecting method has been gradually used in the study of corona performance,and it can detect the corona without contacting,so it can resist environment disturbances very well.However,up to now,the question whether the UV light can exactly reflect the condition of corona has not resolved and the relativity between the corona and UV light has not been studied.In this paper,the relativity between the corona current pulses and the corona pulses of UV light is investigated.The corona UV light is received by photomultiplier tube(PMT)and the corona current is received by a sampling resistance.The experimental results show that:in short distance,the intensity of UV light is inverse proportioned to the square of the detecting distance and the intensity of UV light can be detected exactly in short detecting distance.Meanwhile,the result displays that,wherever corona exists on pin-plate of composite insulators,the number statistic of the UV corona pulses is correlated well with the current pulses,and the magnitude performance between the two pulses is correlated well too.So the UV detection method can be used well in the study of corona performance,and UV light can be taken as a new detecting element instead of the current pulses.