Structural control of seismically induced pounding of elevated bridges by using magnetorheological dampers
Anxin Guo,Liu Cui,Hui Li
2006-01-01
Abstract:Pounding between the adjacent members of the elevated bridges is an important factor that affects the safety of the bridges under modern to strong earthquakes due to the differences in dynamic characteristic of the adjacent structures and spatial variability of the ground motions. The exchange of the velocity during pounding can induced abrupt acceleration change in the adjacent frames of the elevated bridges, and the impact of the girders or the slabs of the highway bridges can generate huge additional forces to the members resulting in the spalling of concrete and the damage of the piers and abutments, even the unseat of the bridge girders. The aim of this study is to investigate the possibility of using MR dampers to suppress the collision between the adjacent segments of the elevated bridge in seismic events. Finite element model of an elevated bridge is established, and the dynamic responses of the uncontrolled structures with different gap size of the expansion joints are investigated firstly to analyze the effects of the collision of the deck. Then, dynamic analyses for structure with MR dampers are also conducted to investigate the performance and effectiveness of the MR dampers for suppressing the collision of the bridge. Semiactive control strategy of the MR dampers is designed and used to manipulate the actuators. The simulation results show that the semiactive control system by using MR dampers can effectively reduce the structural responses if the control system is appropriately designed. Finite element model of an elevated bridge is established by using the ANSYS code. In this model, the decks of this bridge are assumed to be linear in this analysis because the inertia force generated in the decks due to earthquake mainly acts in the longitudinal direction. For the columns of the bridge, the nonlinear properties are modeled by using two plastic hinges at the two ends. The collision of the adjacent segments of the bridge is modeled using the Combin40 element integrated in the ANSYS code. The analysis results show that collision between the adjacent segments of the elevated bridge can induce huge impact forces, which will resulting the spalling of the concrete at the expansion joints. The shear forces and the moments are also not significantly changed with different gap size of the expansion joints. The results indicate that the variation of the gap size cannot affect the shear forces and the moments significantly, and the huge impact forces generated in the superstructure are not transmitted to the bridge columns. This result is similar as that obtained which indicated that although the impact forces are large in magnitude they are quite short in duration compared with the longitudinal period of the bridge segments. The semiactive control system is designed based on the assumption that no collision will occur at the expansion joint with the installation of the devices. To simplify the control system design, the structural is also assumed to be linear with providing damping by the MR dampers. According to the above assumption, the governing equation of motion of the bridge can be given as MẌ + CẊ + KX = -MDSẍg + BS US (1) where M, C and K are the mass, damping and stiffness matrices, respectively; X is the displacement vector of the superstructure; Ẋ and Ẍ are the corresponding velocity and acceleration vectors, respectively; Ds is the excitation influence vector and F is the excitation vector of the ground, and Bs is the MR location vectors; Us is the force generated by the MR damper. BsUs can be expressed by equation as follow BsUs = -CdẊ + B sFdy (2) where the first term at the right is the viscous damping force generated by the MR damper, and the second term is the coulomb force. Then the governing equation of motion of the bridge can be given as. MẌ + (C + Cd)Ẋ + KX = -MDsẍg + BsFdy (3) The control strategy of the semiactive control system is designed to determine the control force of the MR damper by tracing the optimal control force obtained by using the LQG control algorithm. According to the control strategy of the control system, the control force of the MR dampers can be obtained as follow: (1) An optimal control algorithm of the system designed firstly by using the LQG control algorithm; (2) The determined control force is assumed to be the optimal semiactive control forced, and the control force should be provided by the MR dampers as much as possible; (3) Decide the control electricity and voltage of the dampers. According to the above control strategy, the performance of the semiactive control system will achieve the best if the MR damper can accurately provide the same optimal control force determined by using the LQG algorithm. However, due to the shortcoming of the semiactive control system it cannot achieve at all time. So, Hrovat optimal controller algorithm is adopted to trace the optimal control force, and it can be expressed as (Equation Presented) in which ud = cd\ẋ\+ Fdy max is the maximal control force generated by MR damper according to the optimal control force. A semiactive control system for eliminating the pounding of the elevated bridge is designed according the above method. Numerical simulation of the elevated bridge with gap size of 5 cm of the expansion joint is conducted by using the semiactive control system. The analysis result show that the shear force decrease from 1.29 × 106 N to 1.00 × 106 N at the base of the middle segment piers of the elevated bridge, and the moment also decrease from 2.84 × 107 Nm to 2.22 × 107 Nm with the installation of the MR dampers. To validate the linear assumption of the control system design, the time history of the control force obtained in the simulation is saved. The nonlinear analysis of the elevated bridge is also conducted by using the ANSYS code, in which the saved control force time history is applied as axial force in the expansion joint in the analysis. The simulation results show the assumption is acceptable and accurate in the practice of engineering. © 2006 Taylor & Francis Group.