CYCLIC LOADING TEST OF DUMBBELL-SHAPED EXTENDED END-PLATE CONNECTIONS

Wang Zhe,Shi Gang,Fan Hao,Song Wenjing
DOI: https://doi.org/10.7617/j.issn.1000-8993.2013.10.027
2013-01-01
Abstract:To investigate the seismic behavior of a practical dumbbell-shaped extended end-plate connection without end-plate stiffener,three full-scale specimens were tested under cyclic loading.The experimental results indicated that the hysteretic curves of these three specimens were consistently stable whose ductility ratio exceeded 8.0.The equivalent interstory drift angle achieved about 0.07 rad.For the using of thin beam flange,the failure mode was the rupture of the top beam flange along the root of the horizontal fillet weld of the continued plate and the rounded corner of the rolled section in the vicinity of the extended bolt-row,and the shear buckling with different degree occured in the nodal zone.The tested end-plate connections showed excellent performance under cyclic loading,which could be used in high seismic zone.
What problem does this paper attempt to address?