Finite Element Analysis on Retrofitting End-plate Connections

Yang Wen,Shi Yong-jiu,Wang Yuan-qing,Shi Gang
DOI: https://doi.org/10.3969/j.issn.1002-8412.2006.01.020
2006-01-01
Abstract:Experimental results of end-plate connections showed that this type of connections have efficient load capacity,but with low stiffness.Under cyclic loads,the failure modes were controlled by the fracture of bolts,leading to a brittle behavior.To achieve higher joint stiffness and ultimate capacity and improve seismic resistant performance,stiffeners were applied to the panel zone in addition to the fillet weld between column flange and end-plate.Finite element analysis indicates that after reinforcement,a more stiffer connection was obtained under monotonic loading,and better hysteresis loops are observed under cyclic loads with large plastic rotation formed by the local buckling of the beam flange near the column face.This retrofitting scheme employs fillet weld,which has lower toughness,may also suffer brittle failure.Smaller size of weld is recommended and the quality should be guaranteed in order to reduce the residual stress of the fillet weld.
What problem does this paper attempt to address?