Multi-paths Ultrasonic Flow Measurement System with High Precision

YANG Yuan,GAO Yong,YU Ning-mei
DOI: https://doi.org/10.3969/j.issn.1005-9954.2005.06.019
2005-01-01
Chemical engineering
Abstract:In order to satisfy the flow measurement precision for big-pipe,multi-paths ultrasonic flow measurement system based FPGA(Field Programmable Gate Array) and phase lock loop(PLL) was developed.The system used FPGA as the main logic control chip,computer as the operation consol,and singlechip AT89C52 as the communication hinge between the computer and FPGA.AT89C52 transfered the the measurement data of multiple ultrasonic paths based PLL from FPGA to computer,and the computer then calculated the flow.The adoption of PLL improves the clock phase precision leading to improving the measurement precision of the travel time.The system precision analysis showed that the flow measurement error is less than 0.25%.