Method of Ultrasonic Flow Rate Measure Based on Delta-T and TDC-GP2

YAO Bin-bin,ZHANG Hong-jian,TANG Xiao-yu,ZHOU Hong-liang
DOI: https://doi.org/10.3969/j.issn.1001-9944.2011.08.005
2011-01-01
Abstract:Delta-T method ultrasonic flow meter measures the flow rate through the measurement of the value of the Delta-T,which was the ultrasonic flow meter transmission time difference of the downstream and upstream,so the measurement of the transmission time was the key of the system.In order to improve the accuracy of time measurement,TDC-GP2 high precision time measurement chip was chosen in this paper.This paper introduces the flow measurement principle of Delta-T ultrasonic flow meter based on the TDC-GP2 chip and the implementation of corresponding hardware measurement circuit.After the experiment,this method has high measuring precision and resolution ratio and was promising to be applied.
What problem does this paper attempt to address?