Determination of Vitamin A in Micro-Amount of Human Blood by High Performance Liquid Chromatography

CHEN Dong,ZHANG Rui-yun,YANG Liu-hua,SUN Cheng-jun
DOI: https://doi.org/10.3969/j.issn.1000-0720.2008.03.021
2008-01-01
Abstract:A method for the determination of vitamin A in the micro-amount of human blood by high performance liquid chromatography was reported in the paper.50 μL of whole blood sample was added to a 1.5 mL Eppendorf centrifuge tube and then 100 μL anhydrous alcohol was added to precipitate protein,the mixture was shaken by vortex and then vitamin A in the solution were extracted with 400 μL hexane for two times.After centrifuged at 12000 rpm for 3 min,the hexane layer was taken out and blown to dryness under gentle N2 gas.The residue was redissolved with 100 μL methanol and determined by HPLC.The analytical column used was Zorbax (C8,4.6 mm×15 cm,5 μm) and detection wavelength was 325 nm.Mobile phase was methanol-water(92∶8),flow rate was 0.80 mL/min and the temperature was 60 ℃.The range of correlation coefficients for the standard curves were large than 0.999;the detection limit of the method is 0.02 μg/mL.The recoveries of the method ranged from 88% to 115%.The method has been used for the determination of 27 adult whole blood and their corresponding serum samples and found that the vitamin A content in their whole blood were 0.213±0.062 μg/mL(x-±s) and the vitamin A content in their serum were 0.619±0.189 μg/mL(x-±s),with a ratio of 2.907±0.160 μg/mL(x-±s).The method was sensitive,accurate and has been applied to the determination of vitamin A in the micro-amount of human blood.
What problem does this paper attempt to address?